Midea MTA-76C(H)RN1 Technical Manual page 131

R410a t3 top-discharge split type series 50hz
Table of Contents

Advertisement

MCAC-UTSM-201501
3) Supplied assemblies on the site
Name
4-core shielded cable
86 Electrician box
Wiring tube (Insulating sleeve
and tightening screw.)
4) Installation procedure
The installation manual contains information about the procedure of installing wired
controller. Please refer to indoor unit installation manual for connecting between wired
controller and indoor unit.
Circuit of wired controller is low voltage circuit. Never connect it with a standard 220V or
380V circuit or put it into a same wiring tube with the circuit.
The shield cable must be connected stable to the ground, or transmission may fail.
Don not attempt to extend the shield cable by cutting, if it is necessary, use terminal
connection block to connect.
After finishing connection, do not use mugger to have the insulation check to the signal wire.
Wired remote controller structure size figure ( Unit: mm):
Midea R410A T3 Top-discharge Split Type Series 50Hz
Qty (Embedded
Specification (Only
into wall)
1
1
1
Rear view
for reference)
2
0.5mm
×4
The longest is 15m.
\
\
Remarks
\
\