LEAKAGE TEST

Gas connections on the appliance are leak tested at the factory prior to
shipment. Possible mishandling of the appliance during the shipment might
contribute to product integrity as a whole. A complete gas leakage test must
be performed again at the installation site. Please follow the procedure below
for leakage test.
Make a soap solution of one part liquid detergent and one part water. The
-
soap solution can be applied with spray bottle, brush or rag. Soap bubbles
will appear where a leak is present.
Make sure the control tap is in the "OFF" position (full disk = ●) on the
-
control panel.
Turn on the gas supply and check for bubbles from the hoses and
-
connections. Presents of bubble means that a leak path is present.
If a leak is present, turn OFF the gas supply immediately, tighten any
-
leaking fitting carefully, turn gas again and recheck.
Never leak test while smoking.
-
INSTALLATION
Important safety requirements:
THIS APPLIANCE OUTDOOR USE ONLY
5. This appliance shall not be installed or used indoors, in buildings, garages
or any other enclosed area.
6. DO NOT place articles on or against this appliance.
7. DO NOT use or store flammable materials near this appliance.
8. DO NOT operate this appliance unless it is fully assembled with reflector
and protection guard in place.
9. Installation and repair should be done by a qualified service person. The
appliance must be inspected before use and at least annually by a qualified
service person. More frequent cleaning may be required as necessary. It is
imperative that control compartment, burners and circulating air passages
of the heater and light be kept clean.