13) Position adjustment of hook needle guard

After moving the needle bar to the lowest position, check if the needle① touches the needle guard② by about 0.1~0.2 mm. For
adjustment, turn the fixing screw③ of the needle guard in a clockwise direction to push the needle guard② away from the needle, and
turn it counterclockwise to pull the needle guard② closer to the needle.
By 0.1~0.2 mm

14) Height adjustment of the auxiliary presser foot

Normally the auxiliary presser foot② lifts 9 mm off the needle plate when the pressure bar lifter① is raised.
A. Raise the pressure bar lifter①, unfasten the pressure-adjusting screw③ and bring up the auxiliary presser foot② 9 mm off the surface
of the needle plate.
B. Loosen the fixing screw⑥ of the pin⑤ attached onto the pressure bar lifter bracket④.
C. Move the pin⑤ close to the bracket④ towards the arrow direction and fasten the fixing screw⑥ securely afterwards.
28
[ Fig. 46 ]
9㎜
[ Fig. 47 ]