Note 2) Disconnecting flat cable from J9
To disconnect the flat cable;
1. Release the locking tabs by pushing the tabs toward the cable. Excess force will
damage the connector.
2. Pull out the cable.
To connect the cable, reverse the above procedure.
Release tabs.
Note 3) Disconnecting flat cable from FDD connecter
To disconnect the flat cable;
1. Release the locking tabs by pushing the tabs toward the cable. Excess force will
damage the connector.
2. Pull out the cable.
To connect the cable, reverse the above procedure.
Fig.3.1.13 FDD connector
Fig.3.1.12 Flat cable connector, J9
3-7
3.1 Terminal unit, IC-215
Flat cable
Pushing with equality power
about 1mm slowly.
1 mm