Contents Precautions.......................... 1 Features of This Unit ...................... Names and Functions......................4 Connections........................10 Operations ......................... 14 How to Use Remote Control ....................16 Block Diagram ........................18 Specifications ........................19 Before Asking for Repair Services ..................0...
Precautions NTEGRATED AMPL FIER L-505uX Installation place Cautions in connecting speakers This unit shall be installed in a well-ventilated and When making speaker system connections, exercise + - effectively heat-released place. extra care not to short-circuit between of the speaker terminals and speaker input terminals of this Especially, installation of this unit where direct unit.
Features of This Unit LECUA-WM - LUXMAN Electric Controlled Parallel speaker relays Ultimate Attenuator - Waiting Matrix This unit is equipped with large type of parallel speaker relays with a low resistance value to reduce Mounted with Electrically controlled attenuator for gaining the impedance of the speaker output lines.
Page 5
Round pattern board New standard size After careful consideration of delicate audio signal This unit has been manufactured based on LUXMAN's flow, a round pattern board has been applied to new standard size (440mm wide, common with a series of separate amplifiers and a series of SACD achieve smooth signal transmission.
Names and Functions Front panel 1. Operation switch (OPERATION) 4. Input indicator Toggles the power on and off. Lights up at the input device to be selected with the input selector or remote control. When wiring or connection is performed, be sure to turn off this switch.
Page 7
NTEGRATED AMPL FIER L-505uX 8. Headphone jack (PHONES) 10.Line straight switch (LINE STRAIGHT) Insert the headphone plug into this output jack. Even Enhances the purity of the sound quality by passing when the plug is inserted, signals to the speaker the balance control circuit, tone control circuit, or the like.
Page 8
Names and Functions 13.Tone control for bass (BASS) 16.Cartridge selector (CARTRIDGE) Controls the frequency characteristics in the low- Changes the gain level of the equalizer amplifier (amplifier circuit required to play an analog record). frequency range. Selects an MC (moving coil) type cartridge When this switch is set to the center position, flat frequency characteristic is obtained.
Page 9
NTEGRATED AMPL FIER L-505uX Display 1. Monitor indicator (MONITOR) 5. Remote sensor (REMOTE) Receive signals from the accessory remote control. Lights up when the monitor switch is on. 6. Line straight indicator (LINE STRAIGHT) . Power meters Lights up when the line straight switch is on.
Page 10
Names and Functions Rear panel 1. Signal ground (ground terminal) (SIGNAL 3. LINE-1, LINE-, LINE-3, and LINE-4 input GROUND) terminals (unbalance) (LINE-1, LINE-2, LINE-3, LINE-4) Is a ground terminal for devices to be connected to this unit. This terminal is used to reduce noise Are used for high-level signal inputs from a CD when other devices are connected.
Page 11
NTEGRATED AMPL FIER L-505uX 5. Pre-out terminal (PRE OUT) 9. AC inlet (AC IN) This terminal is used to obtain the output of the Connects the accessory power cable. The power preamplifier. shall be supplied from a household wall socket.
NTEGRATED AMPL FIER L-505uX Before connecting How to connect speakers Before connecting to other devices, please connect Connect the left-channel speaker to the LEFT the supplied power cable jack to the AC inlet of SPEAKER terminal of this unit and the right- this device.
NTEGRATED AMPL FIER L-505uX How to connect record player When you need not toggle an input source to be recorded (especially when a recorder connected to Connect between the output terminal of an analog the recorder output terminals is recording), do not record player and the PHONO terminal of this unit with 2 (R and L) pin-plug cables.
Operations Before operation How to operate the tone control 1. Ensure that the connections are correctly performed. This unit has the tone control function for the low- (Normal playback cannot be achieved with wrong frequency and high-frequency ranges. + - connection of R, L, , or The low-frequency range type works in the 300 Hz...
Page 17
NTEGRATED AMPL FIER L-505uX Procedure of timer-controlled recording Memory 1. Turn on the operation switch to activate this unit. This unit stores the following items when the power is off: . Select a source to be recorded under timer control...
3. Monaural switch (MONO) Pressing this button again to set the mute function to off allows sound to be generated. This switch is not operated in L-505uX. 6. Meter switch (METER) Turns off the meter lights. Pressing this switch again turns on the meter lights again.
NTEGRATED AMPL FIER L-505uX 7. Subsonic switch (SUBSONIC) 11.Volume (VOLUME, , ) This button is used to adjust the sound volume. The This switch is not operated in L-505uX. sound volume is lowered with and raised with . 8. Loudness switch (LOUDNESS)
Before Asking for Repair Services While the unit is used, an unusual phenomenon may be confused as a malfunction for a certain reason. Prior to asking us for repair services, please check the table below and read the instruction manual for the subsidiary devices. If the cause of the malfunction cannot be identified, please contact your dealer.
Need help?
Do you have a question about the L-505uX and is the answer not in the manual?
Questions and answers