  • Page 1: Installation Guide

    AT-FS705PD Fast Ethernet Switch Installation Guide PN 613-50465-00 Rev B...
  • Page 2 Copyright © 2004 Allied Telesyn, Inc. 960 Stewart Drive Suite B, Sunnyvale CA 94085, USA All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn, Inc. Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners.
  • Page 3: Electrical Safety And Emission Compliance Statements

    Declares that the product: Fast Ethernet Switch Model Numbers: AT-FS705PD This product complies with FCC Part 15B, Class B Limits: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device must not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 4 Electrical Safety and Emission Compliance Statements RFI Emission FCC Class B, EN55022 Class B, VCCI Class B, C-TICK Immunity EN55024 Electrical Safety EN60950 (TUV), UL60950 ( ), CE Important: Appendix B contains translated safety statements for installing this equipment. When you see the , go to Appendix B for the translated safety statement in your language.
  • Page 5: Table Of Contents

    Table of Contents Electrical Safety and Emission Compliance Statements .....iii Table of Contents .................... v Welcome to Allied Telesyn ................vii Where to Find Related Guides................. vii Documentation Conventions ................vii Contacting Allied Telesyn ................viii Online Support ..................viii E-mail and Telephone Support..............viii Returning Products ..................viii For Sales or Corporate Information ............viii Chapter 1...
  • Page 6 Installing the Switch on a Desktop..............15 Wall-Mounting the Switch ................17 Warranty Registration ..................20 Chapter 3 Troubleshooting .................... 21 Appendix A Technical Specifications ................23 Physical ......................23 Environmental ....................23 Electrical Rating ....................23 Agency Compliance................... 24 Pinout Assignments..................
  • Page 7: Welcome To Allied Telesyn

    Welcome to Allied Telesyn This guide contains instructions on how to install and configure the AT-FS705PD Fast Ethernet Switch. Where to Find Related Guides The Allied Telesyn web site at www.alliedtelesyn.com offers you an easy way to access the most recent documentation, software, and technical information for all of our products.
  • Page 8: Contacting Allied Telesyn

    Welcome to Allied Telesyn Contacting Allied Telesyn This section provides Allied Telesyn contact information for technical support as well as sales or corporate information. Online Support You can request technical support online by accessing the Allied Telesyn Knowledge Base from the following web site: http://kb.alliedtelesyn.com. You can use the Knowledge Base to submit questions to our technical support staff and review answers to previously asked questions.
  • Page 9: Chapter 1 Overview

    10 Mbps or 100 Mbps and in half- or full- duplex mode. The AT-FS705PD switch can be used on a desktop or mounted on a wall. The switch is easy to install and does not require software configuration or...
  • Page 10: Key Features

    Overview Figure 1 illustrates the front and back panels of the AT-FS705PD switch. AT-FS705PD LINK/ACT 5 Port Fast Ethernet Switch 100M Powered Device WALL 24V D C Figure 1 AT-FS705PD Switch Front and Back Panels Key Features The AT-FS705PD switch has the following key features: ❑...
  • Page 11: Status Leds

    AT-FS705PD Fast Ethernet Switch Installation Guide Status LEDs Table 1 defines the LEDs for the switch. Table 1 Status LEDs Color Description LINK/ACT Green A valid link has been established on the port. No link has been established on the port.
  • Page 12: Powering Options

    Option 1: Powered by a 24VDC @ 0.3A+ output wall adapter. Option 1 has higher priority, if both options are connected to the AT-FS705PD, then it is powered by Option 1 and the PWR WALL LED is green. In the same time, the PWR POE LED is either blinking or OFF, which is fully controlled by the Power Sourcing Equipment (PSE).
  • Page 13: Port Speed

    Each twisted pair port on the AT-FS705PD switch can operate in either half- duplex or full-duplex mode. Since these twisted pair ports are IEEE 802.3u- compliant, the duplex mode can be set automatically through Auto- Negotiation.
  • Page 14: Auto Mdi/Mdi-X

    MDI to MDI, you would use a crossover cable. The AT-FS705PD switch features automatic MDI/MDI-X. The twisted pair port automatically determines the configurations of the port on the device to which it is connected and then configures itself appropriately. For example, if a port on a switch is connected to a port on a bridge, which is typically wired as MDI, the port on the switch automatically configures itself as MDI-X.
  • Page 15: Store And Forward

    The MAC address table in the AT-FS705PD switch can store up to 2,048 MAC addresses. To prevent the table from becoming filled with addresses of end- nodes that are no longer active, the switch has a MAC address aging timer.
  • Page 16: Network Topologies

    Overview Network Topologies The AT-FS705PD switch can be used in different topologies such as standalone and uplink. Each topology is describe below. Standalone A standalone topology uses one switch to connect the end-nodes. Figure 3 illustrates a standalone topology that uses an AT-FS705PD switch to connect several workstations and a server.
  • Page 17: Uplink

    AT-FS705PD Fast Ethernet Switch Installation Guide Uplink Figure 4 illustrates multiple AT-FS705PD switches can be interconnected using uplinks from a centralized backbone Fast Ethernet switch. Power Sourcing Equipment (PSE) RS-232 TERMINAL PORT AT-8024 GB Fast Ethernet Switch FAULT 10Base-T/ 100Base-TX...
  • Page 19: Chapter 2 Installation

    Chapter 2 Installation This chapter contains the installation instructions for the AT-FS705PD switch. This switch can be used on a desktop or mounted on a wall. Verifying the Package Contents Make sure the following items are included in your package. If any item is missing or damaged, contact your Allied Telesyn sales representative for assistance.
  • Page 20: Planning The Installation

    Installation Planning the Installation Be sure to observe the following guidelines when planning the installation of your switch. ❑ The end-nodes connected to the twisted pair ports can operate at 10 Mbps or 100 Mbps and half or full-duplex. The switch uses Auto- Negotiation to determine the correct speed and duplex mode for each port.
  • Page 21: Selecting A Site

    AT-FS705PD Fast Ethernet Switch Installation Guide Selecting a Site Be sure to observe the following requirements when choosing a site for your switch. ❑ Select a site that is dust-free and moisture-free. ❑ Be sure that the site will allow you to easily access the switch’s power and data cables.
  • Page 22: Reviewing Safety Guidelines

    Installation Reviewing Safety Guidelines Please review the following safety guidelines before installing the AT-FS705PD switch. Warning Lightning Danger: Do not work on this equipment or cables during periods of lightning activity. Caution Pluggable Equipment: The socket outlet should be installed near the equipment and should be easily accessible.
  • Page 23: Installing The Switch On A Desktop

    AT-FS705PD Fast Ethernet Switch Installation Guide Installing the Switch on a Desktop The AT-FS705PD switch can be used on a desktop or mounted on a wall. To wall-mount the switch, refer to “Wall-Mounting the Switch” on page 17. To install an AT-FS705PD switch on a desktop, perform the following...
  • Page 24 Ethernet port on a PSE device. Note The AT-FS705PD Switch is classified as IEEE Std 802.3af-2003, Environment A, where a LAN or LAN segment, with all its associated interconnected equipment, is entirely contained within a single low- voltage power distribution system and within a single building.
  • Page 25: Wall-Mounting The Switch

    AT-FS705PD Fast Ethernet Switch Installation Guide Wall-Mounting the Switch The switch can be mounted horizontally on a wall using the keyholes on the bottom of the switch. The screws, plastic anchors, and other materials necessary to mount the switch on a wall are not provided.
  • Page 26 Installation Position the switch horizontally onto the wall screws, as illustrated in Figure 7. Figure 7 Positioning The Switch Onto The Wall Screws Connect the twisted pair cables to the twisted pair ports. When connecting a twisted pair cable to a port, observe the following guidelines: ❑...
  • Page 27 AT-FS705PD Fast Ethernet Switch Installation Guide Power ON the switch. There are two ways to power ON the switch; perform one of the following steps: ❑ Using a wall power adapter: Plug one end of the power cord to the 24VDC power connector on the back of the switch and the other end of the power cord to a power outlet.
  • Page 28: Warranty Registration

    Installation Warranty Registration When you have finished installing the switch, you should register your switch by completing the enclosed warranty card and sending it in.
  • Page 29: Chapter 3 Troubleshooting

    Make sure there is no power plug inserted in the 24VDC power port on the back panel of the switch. If the PWR-WALL LED is OFF and the AT-FS705PD switch is connected to a wall adapter, do the following; ❑...
  • Page 30 Troubleshooting ❑ Verify that the end-node connected to the port and the switch are operating at the same speed. Both must be operating at either 10 Mbps or 100 Mbps. ❑ Make sure that the twisted pair cable does not exceed 100 meters (328 feet) and that you are using a Category 3 or better cable for 10Base-T operation or a Category 5 or better cable for 100Base-TX operation.
  • Page 31: Technical Specifications

    Appendix A Technical Specifications Physical Dimensions: W x H x D 125.73 mm x 26 mm x 100.05 mm (4.95 in x 1.02 in x 3.74 in) Weight: 372 grams (0.82 lbs) Environmental Operating Temperature: 0° C to 40° C (32° F to 104° F) Storage Temperature: -25°...
  • Page 32: Agency Compliance

    Technical Specifications Agency Compliance EMI/RFI: FCC Class B, EN55022 Class B, VCCI Class B, C-TICK Electrical Safety: EN60950 (TUV), UL60950 ( , CE Immunity: EN55024 Pinout Assignments Figure 8 shows the pinout assignments for the RJ-45 connector. Figure 8 RJ-45 Pin Assignments Table 4 lists the RJ-45 connector pins and their signals used in Port 1 - Port 4 when these port are operating in either MDI or MDI-X configuration.
  • Page 33 AT-FS705PD Fast Ethernet Switch Installation Guide Table 5 lists the RJ-45 connector pins and their signals used in Port 5 when this port is connected to a PSE device using a straight cable. Table 5 Port 5 RJ-45 Pin Signals (using straight cable)
  • Page 34 Technical Specifications Table 6 lists the RJ-45 connector pins and their signals used in Port 5 when this port is connected to a PSE device using a cross-over cable. Table 6 Port 5 RJ-45 Pin Signals (using cross-over cable) PSE PWR Alternative A Alternative A Alternative A...
  • Page 35: Translated Safety And Emission Information

    Appendix B Translated Safety and Emission Information Important: This appendix contains multiple-language translations for the safety statements in this guide. Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen. Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog.
  • Page 36 Declares that the product: Fast Ethernet Switch Model Numbers: AT-FS705PD This product complies with FCC Part 15B, Class B Limits: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device must not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 37 AT-FS705PD Fast Ethernet Switch Installation Guide RFI Emission FCC Class B, EN55022 Class B, VCCI Class B, C-TICK Immunity EN55024 Electrical Safety EN60950 (TUV), UL60950 ( ), CE Lightning Danger Danger: DO NOT WORK on equipment or CABLES during periods of LIGHTNING ACTIVITY.
  • Page 38 Translated Safety and Emission Information Normen: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen. Hochfrequenzstörung FCC Klasse B, EN55022 Klasse B, VCCI Klasse B, C-TICK Störsicherheit EN55024 Elektrische Sicherheit EN60950 (TUV), UL60950 ( ), CE Gefahr Durch Blitzschlag Gefahr: Keine Arbeiten am Gerät oder an den Kabeln während eines Gewitters ausführen.
  • Page 39 AT-FS705PD Fast Ethernet Switch Installation Guide Standarder: Dette produkt tilfredsstiller de følgende standarder. Radiofrekvens forstyrrelsesemission FCC Klasse B, EN55022 Klasse B, VCCI Klasse B, C-TICK Immunitet EN55024 Elektrisk sikkerhed EN60950 (TUV), UL60950 ( ), CE Fare Under Uvejr Fare: UNDLAD at arbejde på udstyr eller KABLER i perioder med LYNAKTIVITET.
  • Page 40 Translated Safety and Emission Information Eisen: Dit product voldoet aan de volgende eisen. RFI Emissie FCC Klasse B, EN55022 Klasse B, VCCI Klasse B, C-TICK Immuniteit EN55024 Electrische Veiligheid EN60950 (TUV), UL60950 ( ), CE Gevaar Voor Blikseminslag Gevaar: NIET aan toestellen of KABELS WERKEN bij BLIKSEM. Equipement pour branchement electrique, la prise de sortie doit être placée près de l’équipement et facilement accessible".
  • Page 41 AT-FS705PD Fast Ethernet Switch Installation Guide Normes: Ce produit est conforme aux normes de suivantes. Emission d'interférences radioélectriques FCC Classe B, EN55022 Classe B, VCCI Classe B, C-TICK Immunité EN55024 Sécurité électrique EN60950 (TUV), UL60950 ( ), CE Danger De Foudre Danger: NE PAS MANIER le matériel ou les CÂBLES lors d'activité...
  • Page 42 Translated Safety and Emission Information Standardit: Tämä tuote on seuraavien standardien mukainen. Radioaaltojen häirintä FCC Luokka B, EN55022 Luokka B, VCCI Luokka B, C-TICK Kestävyys EN55024 Sähköturvallisuus EN60950 (TUV), UL60950 ( ), CE Salamaniskuvaara Engenvaara: ÄLÄ TYÖSKENTELE laitteiden tai KAAPELEIDEN KANSSA SALAMOINNIN AIKANA.
  • Page 43 AT-FS705PD Fast Ethernet Switch Installation Guide Standard: Questo prodotto è conforme ai seguenti standard. Emissione RFI (interferenza di radiofrequenza) FCC Classe B, EN55022 Classe B, VCCI Classe B, C-TICK Immunità EN55024 Sicurezza elettrica EN60950 (TUV), UL60950 ( ), CE Pericolo Di Fulmini Pericolo: NON LAVORARE sul dispositivo o sui CAVI durante PRECIPITAZIONI TEMPORALESCHE.
  • Page 44 Translated Safety and Emission Information Sikkerhetsnormer: Dette produktet tilfredsstiller følgende sikkerhetsnormer. RFI stråling FCC Klasse B, EN55022 Klasse B, VCCI Klasse B, C-TICK Immunitet EN55024 Elektrisk sikkerhet EN60950 (TUV), UL60950 ( ), CE Fare For Lynnedslag Fare: ARBEID IKKE på utstyr eller KABLER i TORDENVÆR. Utstyr for stikkontakt.
  • Page 45 AT-FS705PD Fast Ethernet Switch Installation Guide Padrões: Este produto atende aos seguintes padrões. Emissão De Interferência De Radiofrequência FCC Classe B, EN55022 Classe B, VCCI Classe B, C-TICK Imunidade EN55024 Segurança Eléctrica EN60950 (TUV), UL60950 ( ), CE Perigo De Choque Causado Por Raio Perigo: NÃO TRABALHE no equipamento ou nos CABOS durante períodos...
  • Page 46 Translated Safety and Emission Information Estándares: Este producto cumple con los siguientes estándares. Emisión RFI FCC Clase B, EN55022 Clase B, VCCI Clase B, C-TICK Inmunidad EN55024 Seguridad eléctrica EN60950 (TUV), UL60950 ( ), CE Peligro De Rayos Eligro: NO REALICE NINGUN TIPO DE TRABAJO O CONEXION en los equipos o en LOS CABLES durante TORMENTAS ELECTRICAS.
  • Page 47 AT-FS705PD Fast Ethernet Switch Installation Guide Standarder: Denna produkt uppfyller följande standarder. Radiostörning FCC Klass B, EN55022 Klass B, VCCI Klass B, C-TICK Immunitet EN55024 Elsäkerhet EN60950 (TUV), UL60950 ( ), CE Fara För Blixtnedslag Fara: ARBETA EJ på utrustningen eller kablarna vid ÅSKVÄDER.