1.
Select the location of the housing. Each ACUIX™ Fixed requires either a 17 to 28
VAC or an 11 to 16 VDC power source measured at the housing. Each ACUIX™
Fixed has a power consumption of 3.5W for the color cameras or 4.5W for the WDR
cameras. Ensure a 24 VAC/12 VDC @ 0.2A power source is available. See
Appendix B, Cable Guidelines
dome.
2.
Remove the ceiling panel at the dome location.
3.
Place the ceiling tile on the dropped ceiling plate. Trim the ceiling tile so you can
press the ceiling tile into the dropped ceiling plate.
4.
Cut a hole in the ceiling tile flush with the hole in the center of the plate.
5.
If necessary, secure a safety cable (supplied by the installer) to a building support
structure. Honeywell recommends using a 3/32" plastic coated aircraft cable.
6.
Insert the housing in the ceiling
a.
Adjust the turning screws on the wing tabs to ensure the space between the
wing tabs and housing flange is greater than the thickness of the ceiling.
b.
Position the wing tabs flat against the housing. Insert the housing through the
hole in the ceiling tile. Using a Phillips screwdriver, turn the two screws in the
housing clockwise to rotate the tabs out and tighten the tabs against the ceiling
tile. The recommended maximum torque is 1–1.25 N-m or 0.74–0.92 lbf-ft or
8.85–11.06 lbf-in.
c.
Insert the housing through the hole in the ceiling, ensuring the wing tabs are flat
against the housing. The recommended maximum torque is 1–1.25 N-m
7.
See
Connecting the Cables
wiring to the interface board in the housing.
8.
See
Installing the Camera Assembly
camera assembly and
installing the lower dome.

In-Ceiling Housing Installation

WARNING!
Installation must be performed by qualified technical
personnel and must be in accordance with all national and
local mechanical and electrical codes.
Perform the following steps to install an ACUIX™in-ceiling housing:
1.
Select the location of the housing. Each ACUIX™ Fixed requires either a 17 to 28
VAC or an 11 to 16 VDC power source measured at the housing. Each ACUIX™
Fixed has a power consumption of 3.5W for the color cameras or 4.5W for the WDR
cameras. Ensure a 24 VAC/12 VDC @ 0.2A power source is available. See
Appendix B, Cable Guidelines
dome.
2.
Cut a 7/15-16" (201.2 mm) diameter hole in the ceiling.
ACUIX
on
page 35
for maximum wiring distances to the
on page
20
for information on connecting the field
on page
21
for information on installing the
Installing the Lower Dome
on page
on
page 35
for maximum wiring distances to the
TM
Fixed Dome User Guide
23
for information on
17

Advertisement

Table of Contents
loading

Table of Contents