F-1

INSTRUCTIONS FOR INSTALLING A RESIDUAL CURRENT DEVICE

TO PROTECT THE 240V SINGLE PHASE RECEPTACLE
1.
TURN OFF THE ENGINE AND DISCONNECT THE NEGATI VE BATTERY CABLE.
2.
REMOVE THE FOUR SCREWS THAT SECURE THE UPPER CONTROL PANEL AND
OPEN THE PANEL.
3.
WHILE HOLDING THE RCD MOUNTI NG BRACKET REMOVE THE TWO SCREWS
SECURING THE COVER PLATE AND RCD MOUNTING BRACKET. SET THE RCD
MOUNTING BRACKET AND SCREWS ASIDE AND DISCARD COVER PLATE.
(SEE FIGURE 1).
UPPER CONTROL
PANEL
COVER PLATE

DIAGRAMS

WARNING
Do not operate with covers removed
Disconnect input power before servicing
Do not touch electrically live parts
Only qualified persons should install,
ELECTRIC
use or service this equipment
SHOCK
CAN KILL
FIGURE 1