A-2

SAFETY PRECAUTIONS

WARNING
Do not attempt to use this equipment until you
have thoroughly read the engine manufacturer's
manual supplied with your welder. It includes
important safety precautions, detailed engine
starting, operating and maintenance instructions,
and parts lists.
------------------------------------------------------------------------
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts or
electrode with skin or wet clothing.
• Insulate yourself from work and
ground
• Always wear dry insulating gloves.
------------------------------------------------------------------------
ENGINE EXHAUST can kill.
• Use in open, well ventilated areas or
vent exhaust outside.
------------------------------------------------------------------------
MOVING PARTS can injure.
• Do not operate with doors open or
guards off.
• Stop engine before servicing.
• Keep away from moving parts.
------------------------------------------------------------------------
See additional warning information at
front of this operator's manual.
Only qualified personnel should install,
use, or service this equipment.

LOCATION AND VENTILATION

The welder should be located to provide an unrestrict-
ed flow of clean, cool air to the cooling air inlets and to
avoid restricting the cooling air outlets. Also, locate
the welder so that the engine exhaust fumes are prop-
erly vented to an outside area.

STACKING

VANTAGE® 500-I machines cannot be stacked.

ANGLE OF OPERATION

Engines are designed to run in the level condition
which is where the optimum performance is achieved.
The maximum angle of continuous operation is 25
degrees in all directions, 35 degrees Intermittent (less
than 10 minutes continuous) in all directions. If the
engine is to be operated at an angle, provisions must
be made for checking and maintaining the oil level at
the normal (FULL) oil capacity in the crankcase.
When operating the welder at an angle, the effective
fuel capacity will be slightly less than the amount
specified.
INSTALLATION

LIFTING

The VANTAGE® 500-I weighs approximately 1345lbs.
(611kg.) with a full tank of fuel 1230lbs.(559kg) less
fuel. A lift bail is mounted to the machine and should
always be used when lifting the machine.
FALLING
EQUIPMENT can
cause injury.
------------------------------------------------------------------------
VANTAGE® 500-I
WARNING
• Lift only with equipment of ade-
quate lifting capacity.
• Be sure machine is stable when lift-
ing.
• Do not lift this machine using lift
bail if it is equipped with a heavy
accessory such as trailer or gas
cylinder.
• Do not lift machine if lift bail is
damaged.
• Do not operate machine while
suspended from lift bail.
A-2