Fluke 345
Power Quality Clamp Meter
The ideal meter for commissioning and
troubleshooting modern electrical loads
With a bright color display to analyze the harmonic
spectrum, a low-pass filter to remove high frequency noise,
and a high EMC immunity design, the Fluke 345 is ideal for
measurements on switching loads such as variable frequency
drives, electronic lighting and UPS systems. Additionally, the
Hall Effect measurement system makes measurement of dc
current possible without the need to break the circuit, and
the internal memory enables long-term logging for analysis of
trends or intermittent problems.
AC/DC current: Clamp-on measurement of ac current up to 1400 A
rms and dc current up to 2000 A without breaking the circuit
Highest safety rating: 600 V CAT IV rated for use at
the service entrance
Accurate in noisy environments: Even with distorted
waveforms present on electronic loads with low-pass filter
Data logging: Identify intermittent faults by
logging any power parameters for minutes or
months, including harmonics
Verify batteries: Direct measurement of dc ripple
(%) for battery and dc systems
Troubleshoot harmonics: Analyze and log
harmonics digitally or graphically
Inrush current: Capture and analyze nuisance tripping,
from 3 seconds to 300 seconds
Easy to use: Easily confirm instrument setup with
large backlit color display of waveforms and trends
3-Phase power: Built in capability for balanced loads
View graphs and generate reports: With included
Power Log software
N10140
PowerMeterStore
www.

Technical Data

Technical Data
1.877.766.5412
.com

Advertisement

Table of Contents
loading

Summary of Contents for Fluke 345

  • Page 1: Technical Data

    With a bright color display to analyze the harmonic spectrum, a low-pass filter to remove high frequency noise, and a high EMC immunity design, the Fluke 345 is ideal for measurements on switching loads such as variable frequency drives, electronic lighting and UPS systems. Additionally, the...
  • Page 2 Harmonics measurements—view key harmonic factors such as distortion factor and total harmonic distortion, as well as individual harmonics up to the 30 harmonic. PowerMeterStore 1.877.766.5412 www. .com 2 Fluke Corporation Fluke 345 Power Quality Clamp Meter Shop for Fluke products online at:...
  • Page 3: Inrush Current

    Flexible and easy to use Analysis and reporting software The 345 measures a wide range of electrical parameters and Designed to quickly view recorded data, the can be used for many applications in today’s modern electrical included Power Log software displays all recorded environment.
  • Page 4: General Specifications

    58 mm diameter Cleaning The unit can be cleaned with an Isopropanol impregnated cloth. Do not use abrasives or other solvents. PowerMeterStore 1.877.766.5412 www. .com 4 Fluke Corporation Fluke 345 Power Quality Clamp Meter Shop for Fluke products online at:...
  • Page 5: Specifications

    All measurements dc and 15 Hz to 1 kHz Maximum overload 10,000 A or rms x frequency 400,000 < Amps rms is a true-rms measurement (ac + dc) PowerMeterStore 1.877.766.5412 www. .com 5 Fluke Corporation Fluke 345 Power Quality Clamp Meter Shop for Fluke products online at:...
  • Page 6: Voltage Measurement

    All measurements up to 30th harmonic (40th harmonic for 15 Hz to 22 Hz) Frequency range F 15 Hz to 22 Hz and 45 Hz to 65 Hz > acrms PowerMeterStore 1.877.766.5412 www. .com 6 Fluke Corporation Fluke 345 Power Quality Clamp Meter Shop for Fluke products online at:...
  • Page 7 0.3 capacitive and 1.0 to 0.3 inductive (72.5° capacitive and 0° to 72.5° inductive) Resolution 0.001 Accuracy ± 3° Frequency range 15 Hz to 22 Hz and 45 Hz to 65 Hz PowerMeterStore 1.877.766.5412 www. .com 7 Fluke Corporation Fluke 345 Power Quality Clamp Meter Shop for Fluke products online at:...
  • Page 8: Frequency Measurement

    Time base 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms/div Refresh rate 0.5 seconds Maximum sampling rate 15.625 kHz PowerMeterStore 1.877.766.5412 www. .com 8 Fluke Corporation Fluke 345 Power Quality Clamp Meter Shop for Fluke products online at:...
  • Page 9 Interface USB Interface to a PC Power Log software for download, analysis, and reporting 345 Upgrade Utility for installing a new firmware version Logging Memory Logging areas Three areas that can be used individually or combined into one large area...
  • Page 10 41 d 21 h 50 m 119 d 18 h 10 m 15 min 62 d 20 h 45 m 179 d 15 h 15 m PowerMeterStore 1.877.766.5412 www. .com 10 Fluke Corporation Fluke 345 Power Quality Clamp Meter Shop for Fluke products online at:...
  • Page 11: Ordering Information

    L200 Probe Light - Small, rugged, and light the L200 easily attaches to any Fluke test probe. Bright white LED illuminates contact area and frees hands for work.

Table of Contents