Hotpoint Ariston C 34S G1 R /HA Operating Instructions Manual page 17

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 14
Adapting the grill
Replacing the grill burner nozzle:
1. Remove the oven burner after loosening screw V
(see fi gure).
2. Unscrew the grill burner
V
nozzle using a special nozzle
socket spanner (see fi gure) or
preferably with a 7 mm socket
spanner, and replace it with a
new nozzle that is suited to the
new type of gas (see Burner and
nozzle specifi cations table).
! Be careful of the spark plug
wires and the thermocouple
tubes.
I
! The oven and grill burners do
not require primary air adjustment.
! After adjusting the appliance so it may be used with
a different type of gas, replace the old rating label with
a new one that corresponds to the new type of gas
(these labels are available from Authorised Technical
Assistance Centres).
! Should the gas pressure used be different (or vary
slightly) from the recommended pressure, a suitable
pressure regulator must be fitted to the inlet hose in
accordance with current national regulations relating to
"regulators for channelled gas".
We recommend cleaning the oven before using it for
the first time, following the instructions provided in the
„Care and maintenance" section.
Table of burner and nozzle specifications
Table 1
Burner
Diameter
Thermal Power
(mm)
kW (p.c.s.*)
Nominal Reduced
Fast
100
3.00
(Large)(R)
Semi Fast
75
1.90
(Medium)(S)
Auxiliary
51
1.00
(Small)(A)
Oven
-
2.80
Grill
-
2.30
Nominal (mbar)
Supply
Minimum (mbar)
Pressures
Maximum (mbar)
*
At 15°C 1013 mbar-dry gas
**
Propane P.C.S. = 50,37 MJ/Kg
Liquid Gas
By Pass
Nozzle
1/100
1/100
(mm)
(mm)
0.7
41
87
218
0.4
30
70
138
0.4
30
52
1.0
46
80
204
-
-
75
167
28-30
***
Butane P.C.S. = 49,47 MJ/Kg
Natural P.C.S. = 37,78 MJ/m³
TECHNICAL DATA
Oven dimensions
(HxWxD)
Volume
Useful
measurements
relating to the oven
compartment
Power supply voltage
and frequency
Burners
Natural Gas
Flow*
Nozzle
Flow*
g/h
1/100
l/h
***
**
(mm)
214
128
286
136
104
181
73
71
76
95
200
119
267
164
114
219
37
20
20
25
17
35
45
25
34x38x44 cm
57 l
width 42 cm
depth 44 cm
height 17 cm
see data plate
may be adapted for use with any
type of gas shown on the data
plate, which is located inside the
flap or, after the oven
compartment has been opened,
on the left-hand wall inside the
oven.
EC Directives: 2006/95/EC dated
12/12/06 (Low Voltage) and
subsequent amendments -
2004/108/EC dated 15/12/04
(Electromagnetic Compatibility)
and subsequent amendments -
2009/142/EC dated 30/11/09
(Gas) and subsequent
amendments - 93/68/EEC dated
22/07/93 and subsequent
amendments - 2002/96/EC.
1275/2008 (Stand-by/ Off mode)
Nozzle
Flow*
1/100
l/h
(mm)
143
286
S S
118
181
A
R
80
95
132
257
139
227
C 34S G1 R /HA
13
C 34S G3 R /HA
6,5
18
GB
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C 34s g3 r /ha

Table of Contents