Panasonic Section 520 Installation And Feature Description page 13

Digital business system section 520 dbs telephony services
Table of Contents

Advertisement

Section 520 - TSAPI
5. Connect the provided serial cable from Port 1 (or Port 2) to the serial port
Figure 2.
Telephony Services Serial Cable Pinout
DB-25
Male
6. Power on the DBS.
DBS-92-520
on the Network Server. The cable must be configured as shown in Figure
2 below. The API port used must match the DBS API Port Type setting
specified in FF1 2# (41-42)# 1# (0-1)# and the port specified with the
NetWare Loadable Module driver "Panadrvr". See "Programming the
DBS" on page 8 and "DBS Driver Installation" on page 9 for more
information.
Note: If the distance from the DBS to the server exceeds 50 feet, line
extenders or short range modems are required.
2
TD
3
RD
4
CTS
5
RTS
6
DSR
8
DCD
7
SG
20
DTR
Issued April 2000
Chapter 3. Installation
2
RD
3
TD
7
RTS
4
DTR
DB-9
Female
5
SG
1
DCD
6
DSR
8
CTS
7

Advertisement

Table of Contents
loading

Table of Contents