Programming The Dbs - Panasonic Section 520 Installation And Feature Description

Digital business system section 520 dbs telephony services
Table of Contents

Advertisement

Chapter 3. Installation

Programming the DBS

1. Enter the DBS programming mode
2. Set the API port to Telephony Services as follows:.
Program
Name
Address
3. Set the Telephony Services API Port Baud rate to the desired baud rate as
Program
Name
Address
8
API Port Type
FF1 2# 1# (41 or 42)# 1# (0-1)#
API Port Number
41 = Port 1
42 = Port 2
Note: The Telephony Services NLM defaults to use the first port (41).
follows:.
API Baud Rate
FF1 2# 1# (41 or 42)# 2# (0-1)#
API Port Number
41 = Port 1
42 = Port 2
Note: If Telephony Services is the only connection to the API card, it is
recommended that the baud rate be set to19200. If both API ports are
used, it is recommended that both baud rates be set to 9600 bps.
Issued April 2000
Section 520 - TSAPI
Port Type:
0 = Standard API protocol (default)
1 = Telephony Services protocol
Baud Rate:
0 = 9600 (default)
1 = 19200