Carrier 38APS025-065 Installation Instructions Manual page 35

Gemini select air-cooled condensing units with puron refrigerant (r-410a) 50/60 hz
Hide thumbs Also See for 38APS025-065:
Table of Contents

Advertisement

SUPPLY
38APD
VOLTAGE
V-Ph-Hz
UNIT SIZE
Min
208/230-3-60
187
380-3-60
342
025
460-3-60
414
575-3-60
518
380/415-3-50
342
208/230-3-60
187
380-3-60
342
027
460-3-60
414
575-3-60
518
380/415-3-50
342
208/230-3-60
187
380-3-60
342
030
460-3-60
414
575-3-60
518
380/415-3-50
342
208/230-3-60
187
380-3-60
342
040
460-3-60
414
575-3-60
518
380/415-3-50
342
208/230-3-60
187
380-3-60
342
050
460-3-60
414
575-3-60
518
380/415-3-50
342
208/230-3-60
187
380-3-60
342
060
460-3-60
414
575-3-60
518
380/415-3-50
342
208/230-3-60
187
380-3-60
342
070
460-3-60
414
575-3-60
518
380/415-3-50
342
208/230-3-60
187
380-3-60
342
080
460-3-60
414
575-3-60
518
380/415-3-50
342
208/230-3-60
187
380-3-60
342
090
460-3-60
414
575-3-60
518
380/415-3-50
342
208/230-3-60
187
380-3-60
342
100
460-3-60
414
575-3-60
518
380/415-3-50
342
208/230-3-60
187
380-3-60
342
115
460-3-60
414
575-3-60
518
380/415-3-50
342
208/230-3-60
187
380-3-60
342
130
460-3-60
414
575-3-60
518
380/415-3-50
342
LEGEND
FLA
— Full Load Amps
ICF
— Maximum Instantaneous Current Flow
LRA — Locked Rotor Amps
MCA — Minimum Circuit Amps
MOCP— Maximum Overcurrent Protection
RLA — Rated Load Amps
NOTES:
1. Units are suitable for use on electrical systems where voltage
supplied to the unit terminals is not below or above the listed
minimum and maximum limits. Maximum allowable phase
imbalance is: voltage 2%; amps 10%.
2. All units/modules have single point primary power connection.
Main power must be supplied from a field-supplied disconnect.
3. For MCA that is less than or equal to 380 amps, 3 conductors
are required. For MCA between 381 and 760 amps, 6 conduc-
tors are required. Calculation of conductors required is based
on 75 C copper wire.
Table 10 — 38APD Standard Condenser Fan Electrical Data
COMPRESSOR
CIRCUIT A
Max
Qty
RLA
LRA
254
48.1
245
418
23.7
145
506
1
18.6
125
632
14.7
100
440
18.6
118
254
51.3
300
418
26.9
139
506
1
23.1
150
632
19.9
109
440
23.1
140
254
55.8
340
418
34.0
196
506
1
26.9
179
632
23.7
132
440
26.9
174
254
35.8
239
418
23.7
145
506
2
17.9
125
632
14.3
80
440
17.9
118
254
51.3
300
418
26.9
139
506
2
23.1
150
632
19.9
109
440
23.1
140
254
51.3
300
418
26.9
139
506
2
23.1
150
632
19.9
109
440
23.1
140
254
55.8
340
418
34.0
196
506
2
26.9
179
632
23.7
132
440
26.9
174
254
55.8
340
418
34.0
196
506
2
26.9
179
632
23.7
132
440
26.9
174
254
51.3
300
418
26.9
139
506
3
23.1
150
632
19.9
109
440
23.1
140
254
55.8
340
418
34.0
196
506
3
26.9
179
632
23.7
132
440
26.9
174
254
55.8
340
418
34.0
196
506
3
26.9
179
632
23.7
132
440
26.9
140
254
55.8
340
418
34.0
196
506
3
26.9
179
632
23.7
132
440
26.9
174
CONDENSER FAN
CIRCUIT B
Total Qty
Qty
RLA
LRA
48.1
245
23.7
145
1
18.6
125
2
14.7
100
18.6
118
51.3
300
26.9
139
1
23.1
150
2
19.9
109
23.1
140
55.8
340
34.0
196
1
26.9
179
2
23.7
132
26.9
174
33.4
225
19.2
140
2
16.7
114
3
13.4
80
16.7
111
51.3
300
26.9
139
2
23.1
150
3
19.9
109
23.1
140
55.8
340
34.0
196
2
26.9
179
4
23.7
132
26.9
174
46.1
245
23.7
145
3
18.6
125
4
14.7
100
18.6
118
55.8
340
34.0
196
3
26.9
179
5
23.7
132
26.9
174
55.8
340
34.0
196
3
26.9
179
6
23.7
132
26.9
174
55.8
340
34.0
196
3
26.9
179
6
23.7
132
26.9
174
73.9
505
38.2
290
3
30.4
225
7
24.6
180
30.4
225
85.3
605
51.9
353
3
41.9
272
8
34.7
240
41.9
272
4. Wiring for main field supply must be rated 75 C. Use copper
conductors only.
a. Incoming wire size range for terminal block with MCA up to
175 amps is 14 AWG (American Wire Gage) to 2/0.
b. Incoming wire size range for terminal block with MCA from
175.1 amps to 420 amps is 2 AWG to 600 kcmil.
c. Incoming wire size range for non-fused disconnect with MCA
up to 100 amps is 14 AWG to 1/0.
d. Incoming wire size range for non-fused disconnect with MCA
from 100.1 amp to 200 amps is 6 AWG to 350 kcmil.
e. Incoming wire size range for non-fused disconnect with MCA
from 200.1 amp to 450 amps is 3/0 to 500 kcmil.
35
REC
MCA
MOCP
FLA
FUSE
6.6
121.4
150
150
3.9
61.1
80
70
3.3
48.5
60
60
2.6
38.3
50
45
3.3
48.5
60
60
6.6
128.6
175
150
3.9
68.3
90
80
3.3
58.6
80
70
2.6
50.0
60
60
3.3
58.6
80
70
6.6
138.8
175
175
3.9
84.3
110
100
3.3
67.1
90
80
2.6
58.5
80
70
3.3
67.1
90
6.6
167.2
200
175
3.9
103.5
125
110
3.3
83.6
100
90
2.6
66.7
80
70
3.3
83.6
100
90
6.6
231.4
250
250
3.9
119.6
125
125
3.3
99.1
110
110
2.6
82.0
100
90
3.3
99.1
110
110
6.6
254.6
300
300
3.9
145.9
175
175
3.3
119.9
125
125
2.6
103.5
125
110
3.3
119.9
125
125
6.6
296.3
300
300
3.9
163.2
175
175
3.3
129.5
150
150
2.6
107.8
125
125
3.3
129.5
150
150
6.6
326.0
350
350
3.9
198.0
225
225
3.3
157.7
175
175
2.6
137.4
150
150
3.3
157.7
175
175
6.6
374.9
400
400
3.9
214.6
225
225
3.3
176.5
200
200
2.6
152.3
175
150
3.3
176.5
200
200
6.6
388.4
400
400
3.9
235.9
250
250
3.3
187.9
200
200
2.6
163.7
175
175
3.3
187.9
200
200
6.6
453.8
500
500
3.9
253.5
300
250
3.3
202.6
225
225
2.6
169.3
175
175
3.3
202.6
225
225
6.6
497.4
500
500
3.9
301.9
350
350
3.3
243.3
250
250
2.6
204.7
225
225
3.3
243.3
250
250
ICF
306.3
176.5
150.2
119.9
143.2
364.5
173.7
179.7
134.1
169.7
409.0
237.8
212.5
160.9
80
207.5
361.4
218.9
186.2
128.8
179.2
467.3
225.0
220.2
166.1
210.2
524.8
299.4
265.3
205.9
260.3
566.5
316.7
274.9
210.2
269.9
596.2
351.5
303.1
239.8
298.1
645.1
368.1
321.9
254.7
311.9
658.6
389.4
333.3
266.1
328.3
866.4
495.7
389.6
318.5
389.6
995.8
590.0
462.9
401.3
462.9