Mounting

Select installation position
Socket welding
Sealing/Screwing
10
4 Mounting

4.1 Mounting procedure

VEGABAR 14 functions in any installation position. It
is mounted acc. to the same guidelines as a manom-
eter (DIN EN 839-2)
According to the application, we recommend block-
ing valve or siphons from VEGA's line of mounting
accessories.
A welded socket is necessary for mounting
VEGABAR 14.
Use the components from the VEGA accessories:
• welded socket G½G, article no. 2.7783
–> Take note of the valid welding standards (seg-
mental welding procedure).
Use the attached seal:
• process fitting GV and GB:
Tesnit 6.2 x 17.5 1, article no. 2.14815, seal in
front of the thread
• process fitting GP:
Klingersil 21 x 30 x 2, article no. 2.5056, seal be-
hind the thread.
Seal the thread with teflon, hemp or a similar resist-
ant seal material:
• process fitting GN.