Arithmetic Operators - HP 4145A Operation And Service Manual

Semiconductor parameter analyzer
Hide thumbs Also See for 4145A:
Table of Contents

Advertisement

SECTION I
Model 4145A
TRhle
l-l.
Srwcifimtions
(Sheet
G of
8)
ARITHMETIC
AND
ANALYSIS
FUNCTIONS
Arithmetic
Functions
:
Arithmetic
expressions
can
be
entered
and
executed
directly
from the front panel.
Results are displayed on the CRT.
Arithmetic
Operators
:
+, -,
*,
/, /-
, EXP
(Napierian
constant),
LOG
(common
log),
LN
(natural
log),
** (exponentiation),
ABS (absolute),
EEX
(scientific
notation),
and A (differential
calculation).
Keyboard
Operation
:
Arithmetic
expressions
are
executed
by
pressing
the EXECUTE key. Results are displayed on the CRT.
USER
FUNCTION
: Up to two
USER
FUNCTION
can be defined
as arith-
metic expressions.
USER FUNCTIONS
are executed
during measurement
and
the results are displayed with measurement
results.
Physical
Constants
:
Three
commonly
used
physical
constants
are
perma-
nently
stored in memory.
The stored value of each constant
has seven-digit
accuracy but only the five most significant
digits are displayed.
q : Electron
Charge,
1.6O2189x1O-1g C
k : Boltzmann's
Constant,
1.380662~10 -2 3 J/ O K
e : Dielectric
Constant
of vacuum, 8.854185~10 -12F/m.
Engineering
Units : m (10V3 ), p (lo+ ), n (lo-' ), p (10-12)
Analysis Functions :
Overlay
Graph
Comparison
:
A GRAPHIC
plot
can
be
stored
and
later
recalled
to obtain
an overlay
comparison
of two measurements.
-A SCHMOO
plot can also be stored,
but when the RECALL
key is pressed, only the stored
plot is displayed.
Pressing
RECALL
a second time
redisplays
the previous
plot.
Only one set of data
can be stored
and scaling
information
is not
included.
Auto
Retrieve
Function
:
Measurement
data
obtained
in any display
mode
is automatically
redisplayed
whenever
the display mode is changed.
However,
when
the
value
of
a measurement
setup
parameter
is changed,
all
measurement
data is cleared.
MARKER
: On a GRAPHICS
plot,
the MARKER
can be moved along a plotted
curve or line.
The X, Y1 , and Y2 coordinates
at the MARKER
location
are
digitally
displayed on the CRT.
INTERPOLATE
: Allows positioning
of the MARKER
between
two measurement
points.
The X, Y1,
and
Ye coordinates
at
the
MARKER
location
are
estimated
and digitally
displayed on the CRT.
CURSOR
:
On a GRAPHICS
plot,
the
CURSOR
is two
intersecting
and
perpendicular
lines which can be positioned
at any point on the graph.
There
are two
GRAPHICS
cursors
: LONG
and SHORT.
The
X, Y 1, and Y2
coordinates
at the CURSOR location
are digitally
displayed on the CRT.
On a SCHMOO
plot
the CURSOR
highlights
the symbol
at a measurement
point and only the Z-axis value is digitally
displayed on the CRT.
On LIST and MATRIX
displays the CURSOR is a moveable
pointer
( b ).
l-10