SECTION III
3-14.
INITIAL
CONTROL
SETTINGS
3-15.
To facilitate
operation,
the instrument
is
automatically
set to the following
initial
control
settings each time it is turned on :
Front Panel Controls :
MEASUREMENT
keys .~~~~~~. OFF
AUTO
SEQ
key
. . . . . . . . . . . . . . . . . OFF
INTEG
TIME keys •~~.~~~~~~~. SHORT
PLOT/PRINT
keys •~~~~~~..~.~ OFF
AUTO
CAL
key
. . . . . . . . . . . . . . . . ON
BLUE
key
. . . . . . . . . . . . . . . . . . . . . . . . . OFF
Internal
Setup :
CRT
Display
.............e.......
MENU
Page
Measurement
Program
l
**=**** GENL
(see note)
PLOT Area ........................
previously
(for external
plotter)
specified
values
Note
Each
flexible
disc
contains
four
different
application
programs,
of
which
GENL
is
one.
Refer
to
paragraph
3-87
for
details
on
the
furnished
applications
programs.
All data stored
on the disc is retained;
that is,
the disc is not erased
when the instrument
is
turned off.
3-l 6. USER-AREA
FILING
OPERATIONS
3-17.
The 4145A uses a 5.25 inch, single-sided,
single-density
flexible
disc
as
the
storage
medium for its MSU (mass storage unit).
Each of
the
five
work-discs
furnished
with
the
4145A
contains
the
necessary
operating
system
software,
four
general
purpose
measurement
programs,
and enough user area for 131 records.
Up to 96 files can be stored in the user-area.
Note
A record
is the
minimum
unit
for
storage
on the disc.
A file consists of
1, 3, or 12 records,
depending
on the
file type.
3-18
Model 4145A
Three
types
of
files
can
be stored
in the
user-area :
1.
Measurement
program
files-file
type P :
Specifying
file type P in the SAVE command
reserves 3 records on the disc and stores the
existing
measurement
setup
(channel
assignments,
parameter
settings,
graphic
scaling,
output
sequence,
etc.)
at
the
reserved
S-record location.
2.
Measurement
data files-file
type D :
Specifying
file type D in the SAVE command
reserves
12 records
on the disc and stores
the
measurement
setup
and measurement
results
(GRAPHICS,
LIST,
nwnux,
or
SCHMOO)
at
the
reserved
12-record
location.
3.
Auto-sequence
program
files-file
type S :
Specifying
file type S in the SAVE command
reserves
1 record on the disc and stores the
existing
auto-sequence
program
at
the
reserved
l-record
location.
For more information
on file types,
number
of
records
used, etc.,
refer
to Figure
3-30, 4145A
FILE
CATALOG
Page.
Four filing
operations-SAVE,
GET, PURGE, and
REPACK-can
be
performed
from
the
front
d
panel.
Each is described below :
SAVE :
Used
to
store
the
existing
measurement
setup (except INTEG TIME, AUTO CAL, and
sof tkey
functions),
the
existing
auto-sequence
program,
output
sequence
setup,
or the
measurement
results.
SAVE
cannot
be
used
when
the
disc
is
write-protected.
Before
saving
a
measurement
setup,
a page check
must be
performed
(refer
to para. 3-44).
To SAVE a
file, press the SAVE key (SAVE will appear
on the Keyboard
Input Line of the CRT) and
input
the file
type
(P, D, or S) and file
name.
The file name can contain
up to six
characters,
of
which
the
first
must
be
alphabetic
and
the
last
five
must
be
alphanumeric.
J
GET :
Used to recall
user-stored
files
from
the
disc.
GET cannot
be used to recall any of
the
furnished
measurement
programs.
To
GET a file from
the user-area
of the disc,
press the GET key (GET will appear on the
Keyboard
Input Line of the CRT) and input
*
the file type (P, D, or S) and file name.
'4