Model 4145A
SECTION III
3
ENTER
Key:
This key is used to enter
parameter
values,
alphanumeric
characters,
special
charac-
ters,
and unit
indicators
displayed
on the
Keyboard
Input
Line
(see Figure
3-5) into
the internal
display buffer.
When this key is
pressed,
data
displayed
on the
Keyboard
Input
Line
is moved
to the display
field
indicated
by the field pointer
( ,> and stored
in the display
buffer.
Data
stored
in the
display
buffer
by the ENTER
key can be
recalled
(redisplayed
on the Keyboard
Input
Line) by pressing the RECALL
Key
19
Up
Q
to 60 characters
can be entered
in o the
buffer,
but
only
27 characters
can
be
displayed
at one time.
To display
the rest
of the buffer
contents,
use the BACK key or
FORWARD key.
3
EXECUTE
Key:
This
key
executes
GET,
SAVE,
PRINT,
PLOT,
PURGE,
and REPACK
commands,
and arithmetic
expressions
displayed
on the
Keyboard Input Line.
Note :
The PURGE
and
REPACK
com-
mands are available
only when the
USER FILE CATALOG
is displayed.
3
CURSOR
Control
Keys : -'
These keys control
the positioning
of the
field
pointer
(b)
and the long
and short
cursors.
(They do not control
the cursor on
the Keyboard Input Line.)
Field Pointer Control :
Pressing the 0
, c> , 0
, or
G key
moves
the
field
pointer
(,)
in
the
indicated
direction.
The
FAST
key
cannot be used for field pointer
control.
Long/Short
Cursor Control :
Pressing the 0
, 0
, 0
, or
0 key
moves
the
cursor
in
the
indicated
direction.
Movement
continues
until the
key is released.
Two direction-keys
can
be pressed simultaneously
to move the
cursor
diagonally.
Pressing
the
FAST
key in conjunction
with one or two of the
direction
keys,
causes
the
cursor
to
move more rapidly.
@
1
MARKER
Control
Dial :
This dial controls
the marker
( @ or *) on
the GRAPHICS
PLOT page.
Rotating
the
dial clockwise
moves the marker
from
the
sweep start point to the sweep stop point.
0
5
AUTO
CAL
KEY:
This key enables continuous
auto-calibration
of the 4145A.
The AUTO
CAL function
is
set to ON (key indicator
lamp on) when the
instrument
is turned on. Refer to paragraph
3-37 for details.
@,
8,
@ DATA
ENTRY
Keys :
These
keys
are
used
to
enter
numeric
values,
arithmetic
operators,
and
engineering
units.
Data entered
with these
keys is displayed
on the
CRT's
Keyboard
Input
Line
and
entered
into
the
display
buffer
by pressing the ENTER key 0
. An
arithmetic
expression
entered
with
these
keys is executed
by pressing the EXECUTE
key.
@
Engineering
Unit Keys :
Four
engineering
units
are
available-m
(milli,
10-S ), u (micro,
1O'6 ), n (nano, 10mg ),
and
p
(pica,
1 O-l2 )-for
use
with
the
numeric keys @.
0
Arithmetic
Operator
and Function
Keys :
Nine arithmetic
operators
and functions
are
available-+,
-,
*,
/, 4-9
a,
(,I,
EEX
(scientific
notation)--for
use in arithmetic
calculations.
Five additional
operator
and
functions
are available
with
the alphabetic
(blue)
keys
:
w
(exponentiation),
LOG,
LN (natural
log),
EXP (natural
base), and
ABS (absolute).
The SPACE
key
is also
included in this key group.
@
Numeric
Keys :
These
keys-0
through
9
and
decimal
point-are
used for
entering
measurement
parameter
values
and
for
making
quick
arithmetic
calculations.
Figure 3-2. Front Panel Features
(Sheet 4 of 6).