7.5 Precaution of Laying Wires

1)
Use a wire stripper to strip off about 25mm of the insulation layer at the end of the wires;
2)
Loosen the screws on the terminal block of the air conditioner;
3)
Use the pliers to bend the end of the wire into a ring shape corresponding the size of the
screw;
4)
Pass the screw through the wire ring and fix it onto the terminal block.

7.6 Procedures for Electrical Wiring Work

1)
Knock the holes in the plate of the chosen direction with the hammer.
2)
Place the rubber ring on the knockout hole.
3)
Let the power cable and transmission line go through the knockout hole.
4)
Connect the power cable of the outdoor unit to the L1, L2 terminals with the sign of the XT1
and as well as the ground screw.
5)
Connect the transmission line of the outdoor unit to the N(1), 2 terminals with the sign of
the XT2.
6)
Fix the power cable and transmission line firmly by cable fixing clip.
7)
Screw the coping plate, front side plate, right connection board, front connection board back.
8)
Cover the through-holes with sealing materials to prevent the water, dust or small animals
going into the outdoor unit.
Caution!
The transmission line and the power cable must be separated and separated with an interval
of at least 2cm; otherwise it may be result in communication problem.
In order to protect the power cable and transmission line from damaging by the hole, the
rubber ring must be placed on the hole. Otherwise, it may cause electrical shock or fire etc.
The power wire and transmission line must be more than one meter away from televisions or
radios which can emit electromagnetic waves to prevent image interference or noise.
Otherwise, the unit maybe cannot work.
Confirm the each cable connected to the terminal screw is exactly and securely after finishing
the electric work.
Fix each ground wire separately with the ground screw.
If the connecting wire is connected to the terminal incorrectly, the unit will not work normally.
Fig. 22