Answer
Yes, and the
Online/Activity
LED is off.
Yes, and the
Online/Activity
LED is blinking.
Table 8
Diagnostics LED status: Front panel disks "Fault/UID" (continued)
NOTE:
See
"FDE considerations" (page
Is a connected host port Host Link Status LED off?
Answer
Possible reasons
No
System functioning properly.
Yes
The link is down.
Table 9
Diagnostics LED status: Rear panel "Host Link Status"
Is a connected port Expansion Port Status LED off?
Answer
Possible reasons
No
System functioning properly.
Yes
The link is down.
Table 10
Diagnostics LED status: Rear panel "Expansion Port Status"
58
Troubleshooting
Possible reasons
The disk drive is offline. A
predictive failure alert may have
been received for this device.
The disk drive is active, but a
predictive failure alert may have
been received for this device.
Actions
•
Check the event log for specific information regarding the
fault.
•
Isolate the fault.
•
Contact an authorized service provider for assistance.
•
Check the event log for specific information regarding the
fault.
•
Isolate the fault.
•
Contact an authorized service provider for assistance.
19).
Actions
No action required.
(see
Link LED
note:
•
Check cable connections and reseat if necessary.
•
Inspect cables for damage. Replace cable if necessary.
•
Swap cables to determine if fault is caused by a defective
cable. Replace cable if necessary.
•
Verify that the switch, if any, is operating properly. If
possible, test with another port.
•
Verify that the HBA is fully seated, and that the PCI slot is
powered on and operational.
•
In the SMU, review event logs for indicators of a specific
fault in a host data path component. Follow any
Recommended Actions.
•
Contact an authorized service provider for assistance.
•
See
"Isolating a host-side connection fault" (page
Actions
No action required.
•
Check cable connections and reseat if necessary.
•
Inspect cable for damage. Replace cable if necessary.
•
Swap cables to determine if fault is caused by a defective
cable. Replace cable if necessary.
•
In the SMU, review event logs for indicators of a specific
fault in a host data path component. Follow any
Recommended Actions.
•
Contact an authorized service provider for assistance.
•
See
"Isolating a controller module expansion port
connection fault" (page
page
85)
62).
60).