The Overview section allows you to view history data for a maximum of 10 years since
the beginning of measurements. You can select parameters and sensors you want to be
displayed in the graph and the graphs can have either daily, weekly, monthly or annual span.
On the left there is a slider that allows changing the displayed time frame. The Overview
section consists of two tabs – "Graphs" (shows graphs of selected variables) and "Minimum
and maximum", which shows the extreme values for a particular time period.
24
Section „Conditions"
The weather station is equipped with two independent relay outputs. Keep in mind that
these relay outputs are intended for low voltages of up to 30 V and maximum current of 0.25
A. If you want to control voltage, you must make sure that the corresponding device uses
relay or contactor intended for the appropriate voltage and electrical current. All control
conditions are set in the conditions editor. The manufacturers carries no responsibility for
consequences of incorrectly set parameters or using inappropriate devices.
25
Section „List of conditions"
This section allows you to easily view the defined conditions. If you want to create a new
condition, use the corresponding icon in the toolbar. The toolbar also shows percentage of
maximum available number of conditions currently set. This will increase as you set more
active conditions. The maximum allowed number of conditions is 16.
Each condition can contain up to 8 items (events, actions) and in the Expert mode it is
possible to create one subsequent event. Actions in the expert mode can use up to 8 time
outputs. The toolbar is displayed above the list of conditions and provides all the tools
available for configuring the conditions, such as:
z number of conditions used
z new condition
User guide for IP Weather Station WARIO ME13
z back, leave without saving
z bin, deleting conditions
z condition configuration
z saving conditions
Display and configuration of the sensors depends on the particular configuration of the
weather station and its type and on the connected peripheries.
New condition
Creating a new condition.
Field – Condition name
Name for the actual condition.
Field – Condition
Configuring whether the default state of the condition is ON or OFF. When OFF is selected,
the condition will not be processed. If set to ON it will be processed immediately after saving.
Field – Editor mode
Editor of conditions is divided into two modes for creating conditions.
Basic mode – simple conditions that consist of a single event and automatically end when
it is met or not met. If you select the output condition on the "Met" tab to ON, the "Not met"
output will automatically be set to OFF.
Expert mode – more detailed specification of conditions with the possibility to define
variable states to the "Not met" and "Met" sections and also variable subsequent states
of events and conditions. Just like in case of the Basic mode, the rules for events are not
continued when met or not met.
It is important to always set the actions so that after the state of the output changes to
ON, after change of the state it does not remain ON. Various states can be specified for
each condition and this includes for example even turning of output when different
conditions are met than those that activated it.
22