Cleaning The Condenser Filter - Porkka F Technical And Service Manual

Table of Contents

Advertisement

Technical and Service manual
Inventus upright refrigerators and freezers

Cleaning the condenser filter

Porkka reserves the right to make product alterations at any time and can not be held responsible for any printing errors or omissions.
(a)
(b)
(c)
22
1. Switch off the cabinet from the main
electrical supply by removing cable and
plug from wall socket. The condenser is
situated on the right hand side of the
machine compartment of the cabinet
when facing the front. Remove the
knurled - head screw on the lower
part of the top front panel, then pivot
the panel (a) upwards on it's hinges
until it is secure, leaving the machine
compartment open. Take care that the
panel will not fall back and cause injury.
2. Push the filter holding bracket (b) down
from the top until it becomes free, then
swing to the right, when you can then
remove the filter and or use a dry brush
or vacuum cleaner to remove dust from
condenser fins.
3. Was the filter (c) with e.g. liquid
detergent, rinse the filter and let it dry,
and then put replace. Switch that cabinet
on only when the front cover has been
replaced in position and screw is back in
place.

Hide quick links: