Technical and Service manual
Inventus upright refrigerators and freezers
User manual - Control unit XW70K AND D50K
Label
Name
AUXILIARY THERMOSTAT
ACH Kind of action for auxiliary relay
SAA Set Point for auxiliary relay
SHy Differential for auxiliary relay
ArP Probe selection for auxiliary relay
Sdd Aux.output working during defrost
ALARMS
Probe setting for temperature
ALP
alarm
ALC Temperature alarms configuration
ALU MAXIMUM temperature alarm
ALL minimum temperature alarm
Temperature alarm and fan
AFH
differential
ALd Temperature alarm delay
Temperature alarm delay with
dot
door open
Delay of temperature alarm at
dAo
0.0 to 23h50min, res. 10 min
start up
Probe for temperat. alarm of
AP2
nP; P1; P2; P3; P4
condenser
Condenser for low temperat.
AL2
alarm
Condenser for high temperat.
AU2
alarm
Differential for condenser
AH2
temperature alarm recovery
Condenser temperature alarm
Ad2
0 to 254 min , 255=nU
delay
Delay of cond. temper. alarm at
dA2
0.0 to 23h50min, res. 10 min
start up
Compressor off because of
bLL
condenser low temperature alarm
Compr. off for condenser high
AC2
temperature alarm
AUXILIARY OUTPUT
tbA Alarm relay disabling
buM Buzzer silencing
ALr = alarm; dEF = do not select it; Lig
=Light; AUS =AUX; onF=always on; Fan=
oA4 TRIAC configuration (28-29)
do not select it; db = do not select it; dF2 =
AoP Alarm relay polarity (oA4=ALr)
DIGITAL INPUT
i1P Digital input polarity
oP=opening;CL=closing
i1F Digital input configuration
EAL; bAL; PAL; dor; dEF; Htr; AUS
did Digital input alarm delay
i2b Second Digital input on base
i2P Digital input polarity
oP=opening;CL=closing
i2F Digital input configuration
EAL; bAL; PAL; dor; dEF; Htr; AUS
d2d Digital input alarm delay
Number of activation of pressure
nPS
switch
Compress and fan status when
odC
open door
Regulation restart with door open
rrd
alarm
Light off during energy saving
LES
status
HES Differential for Energy Saving
OTHER
Adr Serial address
PbC Kind of probe
onF on/off key enabling
dP1 Room probe display
dP2 Second probe display
dP3 Third probe display
dP4 Fourth probe display
rSE Current set point
rEL Software release
Ptb Map code
1598027800 XW70K GB PKK R1.0 10.12.2013doc.docx
Porkka reserves the right to make product alterations at any time and can not be held responsible for any printing errors or omissions.
Range
Default Level
CL; Ht
Ht
Pr2
[-55.0 to 150°C]
5
Pr2
[-67 to 302°F]
[0.1 to 25.5°C]
2
Pr2
[1 to 45°F]
nP; P1; P2; P3
nP
Pr2
n; Y
no
Pr2
P1; P2; P3; P4
P1
Pr2
rE; Ab
Ab
Pr2
[-55.0 to 150.0°C]
110,0 Pr1
[-67 to 302°F]
[-55.0 to 150.0°C]
-50,0 Pr1
[-67 to 302°F]
[0.1 to 25.5°C]
2,0
Pr2
[1 to 45°F]
0 to 255 min
15
Pr2
0 to 255 min
15
Pr2
1,3
Pr2
P4
Pr2
[-55.0 to 150.0°C]
-40
Pr2
[-67 to 302°F]
[-55.0 to 150.0°C]
110
Pr2
[-67 to 302°F]
[0.1 to 25.5°C]
5
Pr2
[1 to 45°F]
15
Pr2
1,3
Pr2
n(0); Y(1)
n
Pr2
n(0); Y(1)
n
Pr2
n=no; Y=yes
y
Pr2
n(0); Y(1)
yes
Pr2
onF
Pr2
do not select it
oP; CL
CL
Pr2
cL
Pr1
dor
Pr1
0 to 255 min
5
Pr1
n , y
CL
Pr1
EAL
Pr1
0
Pr1
0 to 255 min
15
Pr2
0 to 15
F-C
Pr2
no; FAn; CPr; F_C
yes
Pr2
n; Y
no
Pr2
n; Y
0
Pr2
[-30 to 30°C]
0
Pr2
[-54 to 54°F]
1 to 247
1
Pr1
PtC; ntC
ntC
Pr2
nu, oFF; ES
oFF
Pr2
read only
-
Pr1
read only
-
Pr1
read only
-
Pr1
read only
-
Pr1
read only
Pr1
read only
9.4
Pr2
read only
-
Pr2
XW70K
9
6/6