Porkka F Technical And Service Manual page 12

Table of Contents

Advertisement

Technical and Service manual
Inventus upright refrigerators and freezers
Parameters F
Group
Parameter
Regulation
Hy
Regulation
Regulation
US
Probes
Probes
P2P
Probes
oE
Probes
P3P
Probes
o3
Probes
P4P
Probes
o4
Regulation
odS
Regulation
AC
Regulation
AC1
Regulation
rtr
Regulation
CCt
Regulation
CCS
Regulation
Con
Regulation
CoF
Regulation
Regulation
rES
Regulation
rEd
Regulation
dLy
Regulation
dtr
Defrost
tdF
Defrost
dFP
Defrost
dtE
Defrost
idF
Defrost
MdF
Defrost
dSd
Defrost
dFd
Defrost
dAd
Defrost
Fdt
Defrost
dPo
Defrost
dAF
Fan
FnC
Fan
Fnd
Fan
FCt
Fan
FSt
Fan
Fon
Fan
FoF
Fan
FAP
Auxiliary
ACH
Auxiliary
SAA
Auxiliary
SHy
Auxiliary
ArP
Auxiliary
Sdd
Porkka reserves the right to make product alterations at any time and can not be held responsible for any printing errors or omissions.
Description
Differential
LS
Minimum set point
Maximum set point
ot
Air temperature probe calibration
Evaporator (defrost) probe presence
Evaporator (defrost) probe calibration
Condenser probe presence
Condenser probe calibration
Fourth probe presence (not in use)
Fourth probe calibration (not in use)
Delay at start up
Anti-short cycle delay
Second compressor start delay (not in use)
P1-P2 percentage for regulation (not in use)
Continuous cycle duration (not in use)
Set point for continuous cycle (not in use)
Compressor ON time with faulty probe
Compressor OFF time with faulty probe
CF
Temperature measurement unit
Resolution
Probe for Temperature display
Display temperature delay
P1-P2 percentage for display (not in use)
Defrost type
Probe selection for defrost
Defrost termination temperature
Interval between defrost cycles
Maximum time for defrost
Start defrost delay
Display during defrost shows
Display delay after defrost
Draining time
First defrost after start-up (not in use)
Defrost delay after fast freezing (not in use)
Evaporator fan operating mode
Fan delay after defrost
Differential of temperature for forced activation of fans (not in use)
Evaporator fan stop temperature
Evaporator fan on time with compressor off (not in use)
Evaporator fan off time with compressor off (not in use)
Probe selection for evaporator fan
Kind of action for condenser fan (auxiliary relay)
Set point for condenser fan (auxiliary relay)
Differential for condenser fan (auxiliary relay)
Probe selection condenser fan (auxiliary relay)
condenser fan (auxiliary relay) switched off during defrost
12
Koodi/Edit
2
-25
-15
0
yes
0
yes
0
no
0
1
3
5
100
0.00
0
3
20
°C
in
P1
1.00
50
in
P2
6
6
25
0
dEF
20
4
no
0.00
O_n
6
10
30
0
0
P2
CL
28
2
P3
yes