Hotpoint Ariston CG64SG1 I/HA Operating Instructions Manual page 17

Hide thumbs Also See for CG64SG1 I/HA:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 14
regulation screw must be fastened as tightly as
possible.
the knob from the MAX position to the MIN position
quickly or open and shut the oven door, making sure
that the burner is not extinguished.
! Be careful of the spark plug wires and the
thermocouple tubes.
! After adjusting the appliance so it may be used with
a different type of gas, replace the old rating label with
a new one that corresponds to the new type of gas
(these labels are available from Authorised Technical
Assistance Centres).
! Should the gas pressure used be different (or vary
slightly) from the recommended pressure, a suitable
pressure regulator must be fitted to the inlet hose in
accordance with current national regulations relating to
"regulators for channelled gas".
Table of burner and nozzle specifications
Table 1
Burner
Diameter
(mm)
Rapid (R)
100
Semi-rapid (S)
75
Auxiliary (A)
55
Oven
-
Nominal (mbar)
Supply
Minimal (mbar)
pressure
Maximised (mbar)
*
At 15°C and 1013 mbar - dry gas
**
Propane P.C.S. = 50.37 MJ/Kg
***
Butane P.C.S. = 49.47 MJ/Kg
Natural P.C.S. = 37.78 MJ/m³
S
S
R
A
5. Turn
Thermal power
By Pass
kW (p.c.s.*)
1/100
Nomin.
Red.
(mm)
3.00
0.70
1.90
0.40
1.00
0.40
2.60
1.00
CG64SG1 I /HA
CG64SG1 X I /HA
CG64SG1 AG /HA
CG64SG1 X AG /HA
TECHNICAL DATA
Oven Dimensions
HxWxD
Volume
Useful
measurements
relating to the
oven compartment
Voltage and
frequency
Burners
Liquid gas
Nozzle
capacity*
1/100
g/h
(mm)
***
41
86
218
30
70
138
30
50
73
52
78
189
28-30
20
35
31x43,5x43,5 cm
58 l
width 46 cm
depth 42 cm
height 8,5 cm
see data plate
may be adapted for use with any
type of gas shown on the data
plate.
EC Directives 2006/95/EC dated
12/12/06 (Low Voltage) and
subsequent amendments -
04/108/EC dated 15/12/04
(Electromagnetic Compatibility)
and subsequent amendments -
2009/142/EC dated 30/11/09 (Gas)
and subsequent amendments -
90/68/EEC dated 22/07/93 and
subsequent amendments. -
2002/96/EC.
1275/2008(Stand-by/Off-mode)
Natural gas
Nozzle
capacity *
1/100
l/h
**
(mm)
214
116
286
136
106
181
71
79
95
186
119
248
37
20
25
17
45
25
GB
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cg64sg1 x i/haCg64sg1 x ag/haCg64sg1 ag/ha

Table of Contents