PERIODIC MAINTENANCE AND ADJUSTMENT
battery tends to discharge more quickly
if the vehicle is equipped with optional
electrical accessories.
NOTICE
To charge a VRLA (Valve Regulated
Lead Acid) battery, a special (con-
stant-voltage) battery charger is re-
quired. Using a conventional battery
charger will damage the battery. If
you do not have access to a con-
stant-voltage battery charger, have a
Yamaha dealer charge your battery.
To store the battery
1. If the model will not be used for
more than one month, remove the
7
battery, fully charge it, and then
place it in a cool, dry place.
NOTICE: When removing the
battery, be sure the key is
turned to "OFF", then discon-
nect the negative lead before
disconnecting the positive lead.
[ECA16302]
2. If the battery will be stored for more
than two months, check it at least
once a month and fully charge it if
necessary.
3. Fully charge the battery before in-
stallation.
NOTICE
ECA16520
Always keep the battery charged.
Storing a discharged battery can
cause permanent battery damage.
7-32
Replacing the fuses
The main fuse is located behind panel
ECA16530
D. (See page 7-7.)
2
1. Main fuse
2. Spare main fuse
The fuse box, which contains the fuses
for the individual circuits, is located be-
hind panel C. (See page 7-7.)
EAU23542
1