3.3.8 VIBRATION-MOTOR DISASSEMBLY/ASSEMBLY
Procedures
(1) Hold the vibrating part and remove VIBRATION-MOTOR which is fitted into the case.
* For the assembly, reverse the above order.
3.3.9 I-CASE DISASSEMBLY/ASSEMBLY
MAIN-BOARD is attached to I-CASE. I-CASE must be removed after disconnecting all the cables from
LCD and KEY to MAIN-BOARD.
Procedures
(1) Remove one C screw (+, silver).
(2) Peel a fastening tape for FFC-CABLE from KEY and disconnect the cable from the connector.
(3) Hold up I-CASE and disconnect FFC-CABLE and cords from LCD.
(4) Remove the connector from TRIGGER-KEY/L, R.
(5) Hold up and remove I-CASE.
* For the assembly, reverse the above order. < Caution > Do not pull the cords.
(3)
(4)
(2)
(1) C Screw
(2) FFC-CABLE from KEY
(4)
Pull out FFC-CABLE tucked in the case.
Peel a fastening tape and disconnect the cable after
releasing the lock upward.
― 18 ―
VIBRATION-MOTOR
Vib. Part