Condensate Drain; Escape Of Gas; Maintenance - IDEAL LOGIC + Heat 30 User Manual

Hide thumbs Also See for LOGIC + Heat 30:
Table of Contents

Advertisement

Condensate Drain

This appliance is fitted with a siphonic condensate trap system
that reduces the risk of the appliance condensate from freezing.
However should the condensate pipe to this appliance freeze,
please follow these instructions:
a. If you do not feel competent to carry out the defrosting
instructions below please call your local Gas Safe Registered
installer for assistance.
b. If you do feel competent to carry out the following instructions please
do so with care when handling hot utensils. Do not attempt to thaw
pipework above ground level.
If this appliance develops a blockage in its condensate pipe, its
condensate will build up to a point where it will make a gurgling
noise prior to locking out an "L2" fault code. If the appliance is reset
it will make a gurgling noise prior to it locking out on a failed ignition
"L2" code.
To unblock a frozen condensate pipe;
1. Follow the routing of the plastic pipe from its exit point on the
appliance, through its route to its termination point.
Locate the frozen blockage. It is likely that the pipe is frozen at
the most exposed point external to the building or where there
is some obstruction to flow. This could be at the open end of
the pipe, at a bend or elbow, or where there is a dip in the pipe
in which condensate can collect. The location of the blockage
should be identified as closely as possible before taking further
action.
2. Apply a hot water bottle, microwaveable heat pack or a warm
damp cloth to the frozen blockage area. Several applications
may have to be made before it fully defrosts. Warm water can
also be poured onto the pipe from a watering can or similar. DO
NOT use boiling water.
3. Caution when using warm water as this may freeze and cause
other localised hazards.
4. Once the blockage is removed and the condensate can flow
freely, reset the appliance. (Refer to "To Light the boiler")
5. If the appliance fails to ignite, call your Gas Safe Registered
engineer.
preventative solutions
During cold weather, set the boiler stat to maximum, (Must return to
original setting once cold spell is over)
Place the heating on continuous and turn the room stat down to
15ºC overnight or when unoccupied. (Return to normal after cold
spell).
4

escape of gas

Should a gas leak or fault be suspected contact the National
Gas Emergency Service without delay. Telephone 0800 111 999
Do NOT search for gas leaks with a naked flame.
cleaning
For normal cleaning simply dust with a dry cloth.
To remove stubborn marks and stains, wipe with a damp cloth
and finish off with a dry cloth.
DO NOT use abrasive cleaning materials.

maintenance

The appliance should be serviced at least once a year by a Gas
Safe Registered Engineer or in IE a Registered Gas Installer
(RGII).
Ideal Logic + Heat -
User's

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Logic + heat 15Logic + heat 12Logic 30Logic 12Logic 24Logic 15 ... Show all

Table of Contents