Operation; Remote Control - Sealey sac9000.V3 Instruction Manual

Air conditioner, dehumidifier, heater unit
Table of Contents

Advertisement

fig.7

6. OPERATION

6.1.
STANDBY MODE. When the machine is plugged in, it will be placed in standby mode for 3 minutes.
When first switched on it will start up in cooling mode, set at 22ºC, with a low fan speed. The machine mode
can now be changed using the mode key (fig 6.2 / 7.2). When the ON/OFF switch is pressed again the
machine returns to standby mode. If the machine remains in standby mode and is switched on again it will start
up in the last mode selected. If the machine is disconnected from the mains it will start up in the default cooling
mode when next used.
6.2.
COOLING MODE. Press the mode key to cycle through the options until cooling mode is reached indicated by
the snowflake symbol.
6.2.1. Press UP or DOWN (fig.6.5,6.6 / 7.4,7.5) to adjust the temperature.
6.2.2. Press FAN (fig 6.3 / 7.3) to select a higher or lower fan speed.
6.3
HEATING MODE. Press the MODE key to cycle through the options until heating mode is reached indicated by
the sun symbol.
6.3.1. Press UP or DOWN to adjust the temperature.
6.3.2. Press FAN to select a higher or lower fan speed.
6.4.
FAN ONLY MODE. Press the MODE key to cycle through the options until fan mode is reached indicated by the
fan symbol.
6.4.3. Press the FAN key to switch between a low or high fan speed.
6.5
TIMER MODE. In standby mode press TIMER (FIG 6.8/ 7.7) to set the switch ON time (the timer symbol lights).
6.5.1. Repeatedly press the timer key to advance the time in one hour increments from 1 to 24 hours. Stop when the
required switch on time is reached.
6.5.2. To set the power OFF time the machine must be running. The time set will remain valid for all modes.
6.5.3. Press TIMER to set the power OFF time (the timer symbol lights).
6.5.4. When the machine is returned to standby mode the timer settings are cancelled.
6.6
DEHUMIDIFYING MODE. Press the MODE key to cycle through the options until dehumidifying mode is
reached indicated by the water droplets symbol.
6.6.1. The timer and sleep functions cannot be set in dehumidifying mode.
6.6.2. The fan speed is automatically selected at low and cannot be changed.
6.7
SLEEP FUNCTION. Press the SLEEP key (FIG 6.7/ 7.6) to start the SLEEP function indicated by the moon
symbol.
The default fan speed is low. The sleep function is only valid in COOLING mode and HEATING mode. In stand
by and water full conditions, sleep mode is automatically cancelled.
6.7.1. In COOLING mode, the sleep function turns the temperature up by 1°C, one hour after the sleep function is
turned on. The temperature then remains constant.
6.7.2. In HEATING mode, the sleep function turns the temperature down by 1°C, one hour after the sleep function is
turned on. The temperature then remains constant.
6.8.
IMPORTANT! The machine will go into sleep mode for 3 minutes automatically when switching from hot to cold
and vice versa.
© Jack Sealey Limited

Remote Control

1. . . . . . . . . . . . . . . . . . . . . . Power Button
2. . . . . . . . . . . . . . . . . . . . . . .Mode Button
3. . . . . . . . . . . . . . . . . . Fan Speed Button
4. . . . . . . . . . . . . Temperature Plus Button
5. . . . . . . . . . . .Temperature Minus Button
6. . . . . . . . . . . . . . . . . . . . . . Sleep Button
7. . . . . . . . . . . . . . . . . . . . . . Timer Button
Original Language Version
SAC9000.V3
Issue: 4(I) - 11/02/14

Hide quick links: