Water Drainage; Maintenance; Troubleshooting - Sealey sac9000.V3 Instruction Manual

Air conditioner, dehumidifier, heater unit
Table of Contents

Advertisement

7. WATER DRAINAGE

7.1.
EMPTYING THE INNER TANK. When the inner tank becomes full the temperature display (fig.6.10) will show
'E4'
7.1.1. The compressor will shut down and the control panel will become inoperative until the tank is emptied.
7.1.2. Disconnect the machine from the mains supply.
7.1.3. Place a suitable container below the water outlet at the back of the machine.
7.1.4. Pull out the rubber plug (fig.8) and allow the tank to drain. Remove and empty the collection container. Refit the
rubber plug.
7.1.5 Plug the machine back into the mains supply and restart it.

8. MAINTENANCE

WARNING! Switch off the machine and unplug it from the mains power supply before performing any
maintenance or repairs.
8.1.
CLEANING.
8.1.1. Remove the plug from the mains power supply.
8.1.2. Use a soft, damp cloth to clean the machine outer casing. Don't use chemical agents such as benzene, alcohol,
petrol, lighter fuel etc. as these agents may melt / damage the surface of the plastic.
8.1.3. DO NOT splash water into the machine.
8.2.
FILTER.
8.2.1. Clean the filters every two weeks as blocked filters will seriously reduce the efficiency of the machine.
8.2.2 There are two filters situated at the back of the machine.
8.2.3. Clean the filters in warm water with a neutral detergent. Allow them to dry completely before refitting them.
8.2.4. Do not run the machine without filters.
8.3.
SEASONAL CLEANING AND STORAGE
8.2.1. If the machine will be unused for a long period of time, prepare it in the following way.
8.2.2. Empty the internal water tank as described in 7.1.
8.2.3.. Run the machine in fan mode for two hours to dry out the internal machinery.
8.2.4. Turn the machine off and unplug it from the mains power supply.
8.2.5. Remove the filters, clean, dry and reinstall them.
8.2.6. Disconnect the exhaust duct.
8.2.7. Cover the machine with a plastic bag and store in a dry, childproof location

9. TROUBLESHOOTING

PROBLEM
Machine not working
Machine auto restarts frequently
Machine too noisy
Compressor not working
© Jack Sealey Limited
fig.8
CAUSE
Power OFF
'E4' shows on temperature indicator
Timer set
Machine in direct sunlight
Doors and windows are open, many heat
sources in room
Filters too dirty
Air inlets or air outlet is blocked
Machine is not situated on level ground
Compressor heat protection cut out
operated
Original Language Version
SOLUTION
Plug in / turn on power
Drain inner water tank (see 7.1)
Turn off machine for three minutes
then restart it
Shade machine / draw curtains
Close doors and windows, remove
heat sources from room
Clean or replace filters
Remove blockage
Move to flat and solid ground
Wait for 3 minutes, restart the
machine when temperature normal
SAC9000.V3
Issue: 4(I) - 14/02/14

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents