Download Print this page
Sealey SAC9000 Instructions Manual
Sealey SAC9000 Instructions Manual

Sealey SAC9000 Instructions Manual

Air conditioner, dehumidifier, heater unit

Advertisement

Quick Links

Thank you for purchasing a Sealey Product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS,
WARNINGS AND CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH
IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE
THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1.
SAFETY INSTRUCTIONS
1.1.
ELECTRICAL SAFETY
! WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs,
sockets and any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by
the installation of appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the
main distribution board. We also recommend that a Residual Current Device (RCD) is used. It is particularly important
to use an RCD with portable products that are plugged into a supply which is not protected by an RCCB. If in any doubt
consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer.
You must also read and understand the following instructions concerning electrical safety.
1.1.1.
The Electricity at Work Act 1989 requires that all portable electrical appliances, if used on business
premises, are tested by a qualified electrician, using a Portable Appliance Tester (PAT), at least once a year.
1.1.2.
The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe
condition of those appliances and the safety of the appliance operators. If in any doubt about electrical
safety, contact a qualified electrician.
1.1.3.
Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
See 1.1.1. and 1.1.2. and use a Portable Appliance Tester.
1.1.4.
Ensure that cables are always protected against short circuit and overload.
1.1.5.
Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that
none is loose
1.1.6.
Important: Ensure that the voltage marked on the appliance matches the
power supply to be used and that the plug is fitted with the correct fuse -
see fuse rating at right.
1.1.7.
DO NOT pull or carry the appliance by the power cable.
1.1.8.
DO NOT pull the plug from the socket by the cable.
1.1.9.
DO NOT use worn or damaged cables, plugs or connectors. Immediately
have any faulty item repaired or replaced by a qualified electrician. When a
BS 1363/A UK 3 pin plug is damaged, cut the cable just above the plug
and dispose of the plug safely.
Fit a new plug according to the following instructions (UK only).
a) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to t he neutral terminal 'N'.
d) After wiring, check that there are no bare wires, that all wires have been
correctly connected, that the cable outer insulation extends beyond the cable restraint and that the
restraint is tight.
Double insulated products, which are always marked with this symbol
neutral (blue) wires only. To rewire, connect the wires as indicated above - DO NOT connect either wire to the
earth terminal.
1.1.10. Products which require more than 13 amps are supplied without a plug. In this case you must contact a
qualified electrician to ensure that a suitably rated supply is available. We recommend that you discuss the
installation of an industrial round pin plug and socket with your electrician.
1.1.11.
If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is
preferred since any appliance plugged into it will be protected. The cable core section is important and should
be at least 1.5mm
others which may be used in the other output sockets, we recommend the use of 2.5mm
DEHUMIDIFIER, HEATER UNIT
, but to be absolutely sure that the capacity of the reel is suitable for this product and for
2
INSTRUCTIONS FOR:
AIR CONDITIONER,
SAC9000
MODEL NO:
Blue
Neutral
Wire
FUSE RATING 13 AMP
, are fitted with live (brown) and
Yellow & Green
Earth Wire
Brown
Live
Wire
Cable
Restraint
section cable.
2
SAC9000 - 1 - 241106

Advertisement

loading

Summary of Contents for Sealey SAC9000

  • Page 1 SAC9000 MODEL NO: Thank you for purchasing a Sealey Product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.
  • Page 2: Specification

    2. SPECIFICATION Model No: ......SAC9000 Thermostat Range: ....16-35°C Cooling Capacity: .
  • Page 3: Installation

    Place the end of the duct in the opening and if necessary tie it in place. Do not allow the duct to be overstretched. Do not allow the duct to be kinked or distorted or blocked as this will overheat the unit. If the unit becomes overheated it will automatically shut down. Fig.3 SAC9000 - 1 - 241106...
  • Page 4: Operation

    5.2.1 Mode Button. Press the mode button repeatedly to cycle through to the mode of your choice. The appropriate symbol will appear on the display. (See above). SAC9000 - 1 - 241106...
  • Page 5 To set auto on, the main unit must be plugged in to the mains socket. To cancel timer settings advance the time to 12 hours and press the timer button once more to set the display to zero. SAC9000 - 1 - 241106...
  • Page 6: Maintenance

    The hose can be extended if required with 18mm plastic pipe. If the unit is to be unused for sometime be sure to drain all condensed water from the tank. SAC9000 - 1 - 241106...
  • Page 7: Troubleshooting

    Air Conditioner, Humidifier, Heater Unit. Model No: SAC9000 24th November 2006 72/23/EEC Low Voltage Directive 89/336/EEC EMC Directive For Jack Sealey Ltd. Sole importer into the UK of 93/68/EEC Marking Directive Sealey Power Products. 2002/95/EC RoHS Directive 2002/96/EC WEEE Directive NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.