Pump down limit. Limit value where the last compressor is cut out.
Time delay for incorrect cut-out, compressor 1
Time delay for incorrect cut-out, compressor x; x=2, 3 and so on.
Pulse width period for the digital scroll modulation
Max. capacity in the pulse width period
Min. capacity in the pulse width period
Kp factor for PI regulation of the digital scroll
Tn factor for PI regulation of the digital scroll
The digital scroll's capacity compared to one of the other compressors
Proportional band Xp for (P= 100/Xp) condenser regulation
I: Integration time Tn for condenser regulation
Cutin condenser capacity with manual control. See also "n53"
Manual control of condenser capacity (when ON, the value in "n52" will
be used)
Start speed The voltage for the speed regulation is kept at 0V until the
regulation requires a higher value than the value set here.
Min. speed. The voltage for the speed regulation switches to 0V when
the regulation requires a lower value than the value set here.
Alarm
Delay time for a A32 alarm
Low alarm and safety limit for P0
Delay time for a DI1 alarm
Delay time for a DI2 alarm
Delay time for a DI3 alarm
Upper alarm and safety limit for Pc
Upper alarm limit for sensor "Saux1" If a higher value is measured then
the digital scroll stops.
Delay time for a P0 alarm
Delay time for a Pc alarm
Miscellaneous
Controllers address
On/off switch (service-pin message)
Access code
Used sensor type for Saux
1=Internal Copeland NTC. (A fixed resistor must also be fitted.)
2=Pt 1000
Set supply voltage frequency
Manual control of outputs:
0: No override
1-10: 1 will cut in relay 1, 2 relay 2, etc.
11-18: Gives voltage signal on the analog output. (11 gives 1.25 V, and so
on in steps of 1.25 V
P0 pressure transmitter's working range - min. value
P0 pressure transmitter's working range - max. value
Use of DI4-input
0=not used. 1=P0 displacement. 2=alarm function. Alarm="A31"
Operating hours of relay 1 (value time 1000)
Operating hours of relay 3 (value time 1000)
Operating hours of relay 4 (value time 1000
Setting of refrigerant
1=R12. 2=R22. 3=R134a. 4=R502. 5=R717. 6=R13. 7=R13b1. 8=R23.
9=R500. 10=R503. 11=R114. 12=R142b. 13=User defined 14=R32.
15=R227. 16=R401A. 17=R507. 18=R402A. 19=R404A. 20=R407C.
21=R407A. 22=R407B. 23=R410A. 24=R170. 25=R290. 26=R600.
27=R600a. 28=R744. 29=R1270. 30=R417A. 31=R422A. 32=R413A.
33=R422D. 34=R427A. 35=R438A. 36=XP10. 37=R407F
Use of DI5-input
0=not used. 1=Pc displacement. 2=alarm function. Alarm="A32"
Pc pressure transmitter's working range - min. value
Pc pressure transmitter's working range - max. value
Operating hours of relay 5 (value time 1000)
Operating hours of relay 6 (value time 1000)
Operating hours of relay 7 (value time 1000)
* this setting is only possible if data communication module is mounted in the controller
AK-PC 560
Manual RS8GE202 © Danfoss 01-2016
c33
-99.9°C / -1.0 bar 100°C / 60 bar
c77
0 s
c78
0 s
c79
10 s
c80
50 %
c81
10 %
c82
2
c83
40 s
c84
100%
n04
0.2 K / 0.2 bar
n05
30 s
n52
0%
n53
OFF (0)
n54
0%
n55
0%
A03
0 min.
A11
-99°C / -1.0 bar
A27
0 min. (-1=OFF)
A28
0 min. (-1=OFF)
A29
0 min. (-1=OFF)
A30
-10 °C / 0.0 bar
A32
1°C (0=OFF)
A44
0 min. (-1=OFF)
A45
0 min. (-1=OFF)
o03*
1
o04*
-
o05
1 (0=OFF)
o06
1
o12
50 Hz (0)
o18
0
o20
-1 bar
o21
6 bar
o22
0
o23
0.0 h
o25
0.0 h
o26
0.0 h
o30
0
o37
0
o47
-1 bar
o48
6 bar
o50
0.0 h
o51
0.0 h
o52
0.0 h
100°C / 60 bar
240 s
60 s
240 s
60 s
30 s
20 s
100 %
100 %
50 %
10 %
20
5
300 s
50 s
200%
100%
40.0 K / 10.0 bar 10.0 K / 3.0 bar
600 s
150
100%
0
ON (1)
OFF (0)
75%
20%
50%
10%
90 min.
0 min.
30°C / 40 bar
-40°C / 0.5 bar
480 min.
OFF
480 min.
OFF
480 min.
OFF
200°C/200 bar
60.0°C / 60.0 bar
150°C
130°C
480 min.
0 min.
480 min.
0 min.
240
-
100
OFF
2
1
60 H (1)
50Hz (0)
18
0
5 bar
-1.0
199 bar
12.0
2
0
99.9 h
0.0
99.9 h
0.0
99.9 h
0.0
37
0
2
0
5 bar
-1.0
199 bar
34.0
99.9 h
0.0
99.9 h
0.0
99.9 h
0.0
Continued
15

Hide quick links:

Advertisement

loading