Nokia RM-42 Service Manual page 461

Hide thumbs Also See for RM-42:
Table of Contents

Advertisement

RM-42
System Module
Description
Parameter
Differential
VOD
voltage
swing
Operating
fCLK
frequency
Differential
rise and fall
time
Note:
• Common mode voltage is a mean value of high and low states of one single-ended signal.
• Differential voltage swing is differential amplitude between signals of differential pair.
• Differential transitions should be only measured with good equipment (bandwith > 1GHz),
otherwise results will seem too slow.
Description
Parameter
Camera analog
VDD
voltage
Camera digital
VDDI
voltage
Description
Parameter
ExtClk
VIH square
wave
ExtClk
VIL square
wave
ExtClk
p-p
sinusoidal
wave
ExtClk
Frequency
SDA, SCL
VIH
SDA, SCL
VIL
9241872 (Issue 1)
Min
100
1
300
Table 27 Unagi Camera supply voltage characteristics
Min
2.6
1.4
Table 28 Unagi Camera control IF electrical characteristics
Min
0.8 x VDD
0
0.5
0.7 x VDD
0
Company Confidential
Copyright ©2005 Nokia. All Rights Reserved.
Typ
Max
150
200
200
800
Typ
2.8
1.5
Typ
Max
-
VDD
-
0.54
-
1.2
9.6
1.8
VDD
-
0.54
Nokia Customer Care
Unit
Notes
mV
-2
MHz
SW controls
frequency
ps
-3
Max
Unit
2.9
V
1.6V
V
Unit
Notes
V
High-level
input
voltage
V
Low-level
input
voltage
V
Sinusoidal
mode
voltage
swing
MHz
SW
controlled
frequency
V
High-level
input
voltage
V
Low-level
input
voltage
Page 9–43