Tx Iq Self Test (St_Cdsp_Tx_Iq_Test) - Nokia RM-42 Service Manual

Hide thumbs Also See for RM-42:
Table of Contents

Advertisement

Appendix A: RF Troubleshooting

2.3 TX IQ self test (ST_CDSP_TX_IQ_TEST)

TX_IQ_TEST (85) checks that the TXIQ lines between RAP & Vinku are properly connected. If this fails
also power tests and RXIQ loopback will fail.
Tested signals: VBAT_ASIC, TXIP, TXIQ, TXQP, TXQN, DAC_REF1, RFBUS
Error code for this self test is given in format:
0xyy, 0xzz, MeasResult1, MeasResult2, ...
,where 0xyy, 0xzz is the main part of the error code:
ST_CDSP_TX_IQ_TEST
ALL or ANY ERROR
(0x00xx)
Propable cause:
Poor soldering/faulty
VINKU
Poor soldering/faulty RAP
Other possible reasons:
RETU, but since we've
gotten this far
without fails it should be
Company Confidential
Copyright © 2005 Nokia. All rights reserved
0xyyzz
ERRORS
YES
OK
Nokia Customer Care
A-13