  • Page 1 ECOlite 4000 ® GAS SAVER INSTRUCTION FOR USE ® Page 1/12...
  • Page 2: Intended Use

    FOREWORD • The GCE ECOlite 4000 unit is a medical device for conserving oxygen, classifi ed as Class IIa ® pursuant to • Directive 93/42/EEC, concerning medical devices. • Compliance with the basic requirements of Directive 93/42/EEC is on the basis of EN ISO 18779.
  • Page 3: Product Description

    Do not use the device without being trained. Training can be only done by a person with an appropriate education, experience and knowledge that has been also trained by the manufacturer. For further information about training programs, please contact GCE. PRODUCT DESCRIPTION The ECOlite 4000 is an electronic oxygen-dosing device with a built-in alarm function.
  • Page 4: Front View

    membranes are not excessively loaded at the same time. The dosed amount of oxygen will penetrate the alveolus and be assimilated into the blood. Nasal supply Spiral hose cannula with connector - applied part: type BF Battery Mediline compartment ECOlite® 4000 cover (rear side) The connector on the supply spiral hose differs with its function from national standards.
  • Page 5 • Close the battery compartment cover. Batteries LR6 1.5V Battery compartment Alkaline Battery compartment cover ® ® • Fit the spiral hose onto the connector for oxygen inlet into the ECOlite 4000 device by means ® of the square two-button adapter. A click should be felt when it is connected correctly. Pull the hose gently to confirm connection.
  • Page 6: Operating Mode

    6.3 OPERATION 6.3.1 OPERATING MODE The ECOlite 4000 unit can be adjusted for two different operating modes: ® Manual (shown as MANUAL on the display screen) • In this mode the device will be delivering oxygen at the volume set on the display on each inhalation.
  • Page 7: Functional Test

    6.3.4 BLOCKING FUNCTION Key Lock To prevent buttons from being unintentionally pressed, a key lock can be activated by pressing the control buttons + and – simultaneously. To deactivate it, press the control buttons + and – again. Locked flow To change flow blocking: •...
  • Page 8: After Use

    When the cannula is used more times, there is a danger of infection. This product contains the phthalates. GCE s.r.o. dissuade to use this product for children, nursing mothers and pregnant women because these matters are dangerous.
  • Page 9: Maintenance

    Repairs may only be carried out by persons authorised by GCE. Each product sent for a repair to a person authorised by GCE shall be properly packed. The reason for a repair must be clearly specified. A short description of the fault and any reference to the complaint number will be helpful.
  • Page 10: Specifications

    It is strictly forbidden to modify, service or repair the product by personnel not employed or authorized by GCE. 9.4 ENVIRONMENT There are no known risks associated with disposal of the ECOlite 4000 at the end of its lifetime. ®...
  • Page 11: Warranty

    WARRANTY The Standard Warranty period is two years from date of receipt by the GCE Customer (or if this is not known 2 years from time of the product manufacture shown on the product). The standard warranty is only valid for products handled according to Instruction for use (IFU) and general industry good practice and standards.
  • Page 12 GCE Group is one of the world’s leading companies in the field of gas control equipment. The headquarters are in Malmö, Sweden, and the two major supply units are located in Europe and Asia. The company operates 15 subsidiaries around the world and employs more than 850 people.