Emerson Micro Motion 3500 Installation Manual page 17

Controller and transmitter
Hide thumbs Also See for Micro Motion 3500:
Table of Contents

Advertisement

Figure 3-4: Gland nut and clamping insert
6. For connection at the core processor housing, prepare shielded cable as follows (for
armored cable, omit steps d, e, f, g):
a. Strip 4 1/2 inches (114 mm) of cable jacket.
b. Remove the clear wrap that is inside the cable jacket, and remove the filler material
c. Remove the foil shield that is around the insulated wires, leaving 3/4 inch (19 mm)
d. Wrap the shield drain wires around the exposed foil twice. Cut off the excess wire.
Figure 3-5: Shield drain wires wrapped twice around exposed shield foil
e. Place the shielded heat shrink over the exposed shield drain wires. The tubing
f. Without burning the cable, apply heat (250 °F or 120 °C) to shrink the tubing. See
Installation Manual
3/4 in
(19 mm)
Gland nut
Gland clamping
insert
7/8 in
(22 mm)
between the wires.
of foil or braid and drain wires exposed, and separate the wires.
should completely cover the drain wires.
Figure
3-6.
4 1/2 in
(114 mm)
7/8 in
(22 mm)
Shielded heat shrink
Wiring
Gland body
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Micro motion 3300

Table of Contents