Cisco Catalyst 4500 Series Configuration Manual page 1481

Release ios xe 3.3.0sg and ios 15.1(1)sg
Hide thumbs Also See for Catalyst 4500 Series:
Table of Contents

Advertisement

Chapter 65
Configuring Call Home
Table 65-3
Call Home Alert Groups, Events, and Actions
Call Home
Alert Group
Trigger Event
Syslog
SYSLOG
SYSLOG
SYSLOG
SYSLOG
SYSLOG
SYSLOG
SYSLOG
SYSLOG
Environmental
TEMP_FAILU
RE
TEMP_FAILU
RE
TEMP_FAILU
RE
TEMP_FAILU
RE
TEMP_FAILU
RE
TEMP_RECO
VER
POWER_FAIL
URE
POWER_REC
OVERY
POWER_FAIL
URE
OL-25340-01
Syslog Event
Severity Description and CLI Commands Executed
LOG_EMERG
7
LOG_ALERT
6
LOG_CRIT
5
LOG_ERR
4
LOG_WARNING
3
LOG_NOTICE
2
LOG_INFO
1
LOG_DEBUG
0
TempHigh
5
Critical Temp
5
Shutdown Temp
5
Some Temp Sensors
3
Failed
All Temp Sensors
5
Failed
TempOk
5
PowerSupplyBad
5
PowerSupplyGood
5
PowerSupplyFanBad
3
Software Configuration Guide—Release IOS XE 3.3.0SG and IOS 15.1(1)SG
Alert Group Trigger Events and Commands
Event logged to syslog. (Only sent to TAC if syslog
level 0, 1, or 2)
CLI commands executed:
show logging
show inventory
System is unusable.
Action must be taken immediately.
Critical conditions.
Error conditions.
Warning conditions.
Normal but signification condition.
Informational.
Debug-level messages.
Events related to power, fan, and environment sensing
elements, such as temperature alarms. (Sent to TAC.)
CLI commands executed:
show module
show environment
show logging
show power
show inventory
The temperature of the chassis is above the normal
threshold.
The temperature of the chassis has risen above the
critical threshold.
The temperature of the chassis is very high and the
system will be shut down.
Some of the temperature sensors have failed.
All temperature sensors have failed.
The temperature of the chassis is normal.
A power supply has failed or has been turned off.
A failed power supply has been fixed.
A power supply fan has failed.
65-19

Hide quick links:

Advertisement

Table of Contents
loading