OEM TUF-2000F User Manual page 3

Integrated ultrasonic flow meter

Advertisement

TUF-2000F User Manual
Other functions
pipe
Straight pipe
Liquid
Temperature
Turbidity
Flow Direction
Temperature
Environment
Humidity
Twisted Pair Line, standard length of 20m, can be extended to 500m (not recommended);
Cable
Contact the manufacturer for longer cable requirement.
RS-485 interface, transmission distance up to 1000m
Power Supply AC220V or DC24V
Power
Less than 1.5W
Consumption
Protocols
MODBUS, M-BUS, Fuji extended protocol and other factory protocol
1.8 wiring diagram
Analogue output: 4-20mA or 0-20mA current output. Impedance
0 1k. Accuracy 0.1%.
Output
OCT output: Frequency signal (1~9999HZ)
Relay output: over 20 source signal (no signal, reverse flow etc.)
RS485 serial port
Three analogue input
Input
Three-wire PT100 resistor input (optional)
Automatically record the totaliser data of the last 64 days / 64 months /
5 years;
The power-on time and corresponding flow rate of the last 64 power on
and off events. Allow manual or automatic flow loss compensation
The instrument working status of the last 64 days
Steel, stainless steel, cast iron, cement pipe, copper, PVC, aluminum,
material
FRP etc. Liner is allowed
Size
15-6000mm
In the upstream it must be beyond 10D, in the downstream it must be
beyond 5D, in the upstream the length must be beyond 30D from the
section
access of the pump. (D stands for pipe diameter)
Water, sea water, industrial sewage, acid & alkali liquid, alcohol, beer,
Types
all kinds of oils which can transmit ultrasonic single uniform liquid
Standard: -30˚C - 90˚C ,High-temperature:-30˚C - 160˚C
Less than 10000ppm, with a little bubble
Bi-directional measuring, net flow/heat measuring
Main Unit: -30˚C - 80˚C
Transducer: -40 ℃ -110 , Temperature transducer: select on enquiry
Main Unit: 85% RH
Transducer: water-immersible, water depth less than 3m
3