Download Print this page

OEM TUF-2000F User Manual page 23

Integrated ultrasonic flow meter

Advertisement

TUF-2000F User Manual
0062
0062
0072
0077-0078
0079-0080
0081-0082
0083-0084
0085-0086
0087-0088
0089-0090
0092
0093
0094
0096
0097-0098
0099-0100
0101-0102
0103-0104
0105-0106
0105-0106
0113-0114
1
Times for the beeper
1
Pulses left for OCT
1
Error Code
2
PT100 resistance of inlet
2
PT100 resistance of outlet
2
Total travel time
2
Delta travel time
2
Upstream travel time
2
Downstream travel time
2
Output current
1
Working step and
Signal Quality
1
Upstream strength
1
Downstream strength
1
Language used in user
interface
2
The rate of the measured travel
time by the calculated travel
time.
2
Reynolds number
2
Pipe Reynolds factor
2
Working Timer
2
Total working time
2
Total power on-off time
2
Net accumulator
INTEGER
INTEGER
BIT
REAL4
REAL4
REAL4
REAL4
REAL4
REAL4
REAL4
INTEGER
INTEGER
INTEGER
INTEGER
REAL4
REAL4
REAL4
LONG
LONG
LONG
REAL4
23
Writable。Max 255
Writable。Max
65535
16bits, see note 4
In unit Ohm
In unit Ohm
In unit
Micro-second
In unit Nino-second
In unit
Micro-second
In unit
Micro-second
In unit mA
The high byte is the
step and low for
signal quality,
range 00-99,the
larger the better.
Range 0-2047
Range 0-2047
0 : English,
1:Chinese
Other language will
be supported later
Normal 100+-3%
unsigned, in second
unsigned, in second
Unsigned
In Cubic Meter, float

Advertisement

loading