4.4 Custom cord switching procedure

If two wireless remote controls are installed in one room, in order to prevent wrong
operation due to mixed signals, please modify the printed circuit board in the indoor
unit's control box and the remote control using the following procedure. Be sure to modify
both boards. If only one board is modified, receiving (and operation) cannot be done.
( 1 ) Modifying the indoor unit's printed circuit board
Take out the printed circuit board from the control box and cut off jumper wire (J4) using
wire cutters.
After cutting of the jumper wire, take measures to prevent contact with the other the
lead wires, etc.
( 2 ) Modifying the wireless remote control
(a) Remove the battery.
(b) Cut the jumper wire shown in the figure at right.

4.5 Flap and louver control

Control the flap and louver by AIRFLOW
( 1 ) Swing flap
Flap moves in upward and downward directions continuously.
( 2 ) Swing louver
Louver moves in left and right directions continuously.
( 3 ) When not operating
The flap returns to the position of air flow directly below, when operation has stopped.
( 4 ) Multi-directional Air Flow (up/down air scroll and left/right air scroll)
Activating both up/down air swing and left/right air swing at the same time results in a multi-directional air flow.
Up/down air scroll
In COOL, DRY and FAN operation
Stops at this position
for 5 seconds.
Thick line
: moves quickly
Thin line
: moves slowly
( 5 ) Memory flap (Flap or Louver stopped)
When you press the AIRFLOW (UP/DOWN or LEFT/RIGHT) button once while the flap or louver is operating, it stops swinging
at an angle. Since this angle is memorized in the microcomputer, the flap or louver will automatically be set at this angle when the
next operation is started.
·
Recommendable stopping angle of the flap
COOL•DRY
(UP/DOWN) and
(LEFT/RIGHT) button on the wireless remote control.
Horizontal
blowing
14
-
Jumper wire (J6)
Cut
Left/right air scroll
In COOL, DRY and FAN operation
Left louver
Right louver
-
EXTERNAL INPUT
WIRED REMOCON
OPE PERMISSION
CUSTOM
Jumper wire (J4)
AUTO RESTART
LO TEMP
DIRT PREVENT
COOL ONLY
HI CEIL
PANEL
50/60

Hide quick links: