Selection Data; Specifications - Mitsubishi Electric SRK19CIS Technical Manual

Table of Contents

Advertisement

2

SELECTION DATA

2.1 Specifications

Model SRK19CIS (Indoor unit)
SRC19CIS (Outdoor unit)
Item
Cooling capacity
(1)
Power source
Cooling input
Running current (Cooling)
Inrush current
COP
Noise level
Cooling
Exterior dimensions
Height Width
Depth
Color
Net weight
Refrigerant equipment
Compressor type & Q'ty
Motor
Starting method
Heat exchanger
Refrigerant control
(3)
Refrigerant
Refrigerant oil
Deice control
Air handling equipment
Fan type & Q'ty
Motor
Air flow (at High)
Air filter, Q'ty
Shock & vibration absorber
Electric heater
Operation control
Operation switch
Room temperature control
Pilot lamp
Safety equipment
O.D
Connecting method
Attached length of piping
Insulation
Drain hose
P
ower source supply
Recommended breaker size
Size
Connection wiring
Connecting method
Accessories (included)
Optional parts
Notes (1) The data are measured at the following conditions.
Operation
Cooling
The piping length is 7.5m.
(2) The operation data are applied to the 220V.
(3) The refrigerant quantity to be charged includes the refrigerant in 7 m connecting piping.
(Purging is not required even in the short piping.)
If the piping length is longer, when it is 7 to 25m, add 10g refrigerant per meter.
Model
W
kW
A
A
Sound level
dB
Power level
mm
kg
kW
kg
R
W
(Cooling)
CMM
Compressor: overheat protection, Frost protection, Serial signal error protection, Indoor fan motor error
protection
mm (in)
A
Core number
Mounting kit, Clean filter (Natural enzyme filter 1, Photocatalytic washable deodorizing filter 1)
Item
Indoor air temperature
DB
27ºC
SRK19CIS
1 Phase, 220V, 50Hz
Cooling: 3.49
Hi 45, Me 41, Lo 38
60
318
1098
248
Yellowish white
15
Slit fins & inner grooved tubing
Capillary tubes + Electric expansion valve
R22 1.3 (Pre-Charged up to the piping length of 7m)
0.52 (DIAMOND MS56)
Microcomputer control
Tangential fan
1
46
20
Polypropylene net (washable) 2
Wireless-Remote control
Microcomputer thermostat
RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Liquid line: ø6.35 (1/4") Gas line: ø15.88 (5/8")
Flare connecting
Liquid line: 0.70m
Gas line: 0.63m
Necessary (Both sides)
Terminal block (Screw fixing type)
1.5 mm
2
4 cores (Including earth cable)
Terminal block (Screw fixing type)
Outdoor air temperature
WB
DB
19ºC
35ºC
4
-
-
SRC19CIS
5200
1.49
7.4
33
49
65
640
850
Stucco white
46
RH277VHST (Rotary type)
1.3
Line starting
Straight fin & inner grooved tubing
Propeller fan
43
38
Cushion rubber (for compressor)
Connectable
20
WB
24ºC
(220V)
290
1
1
Standards
ISO-T1, JIS C9612

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srk25cis

Table of Contents