Advertisement

USER'S MANUAL
SRK20ZM-S
SRK25ZM-S
SRK35ZM-S
SRK50ZM-S
This air conditioner complies with EMC Directive 2004/108/EC,
LV Directive 2006/95/EC.
Ce climatiseur est conforme à la Directive EMC: 2004/108/EC, LV
Directive 2006/95/EC.
Dieses Kimagerät erfüllt die EMC Direktiven 2004/108/EC, LV
Direktiven 2006/95/EC.
Questo condizionatore d'aria è conforme alla Direttiva EMC: 2004/
108/EC, LV Direttiva 2006/95/EC.
AIR-CONDITIONER
MANUEL DE L'UTILISATEUR
MANUAL DEL PROPIETARIO
GEBRUIKERSHANDLEIDING
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
ANWENDERHANDBUCH
ISTRUZIONI PER L'USO
CONDIZIONATORE D'ARIA
ACONDICIONADOR DE AIRE
AIRCONDITIONING
MANUAL DO UTILIZADOR
APARELHO DE AR CONDICIONADO
ΟΔΗΓΙΕΣ ΧΡΗΣΗΣ
КОНДИЦИОНЕР ВОЗДУХА
KULLANIM KILAVUZU
Este acondicionador de aire cumple con la directiva EMC: 2004/
108/EC, LV Directiva 2006/95/EC.
Deze airconditioner voldoet aan EMC Directive 2004/108/EC, LV
Directive 2006/95/EC.
Este aparelho de ar condicionado está em conformidade com a
Directiva EMC 2004/108/EC e a Directiva LV 2006/95/EC.
∞˘Ùfi ÙÔ ÎÏÈÌ·ÙÈÛÙÈÎfi Â›Ó·È Û‡ÌʈÓÔ Ì ÙȘ ÚԉȷÁڷʤ˜ Ù˘
√‰ËÁ›·˜ EMC 2004/108/EK Î·È Ù˘ √‰ËÁ›·˜ LV 2006/95/EK.
www.serviz-klimatici.com
ENGLISH
FRANÇAIS
CLIMATISEUR
DEUTSCH
KLIMAGERA ¨ T
ITALIANO
ESPAN ˜ OL
NEDERLANDS
PORTUGUÊS
ΕΛΛΗΝΙΚΑ
ΚΛΙΜΑΤΙΣΤΙΚΟ
РУССКИЙ
TÜRKÇE
RLA012A021B

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric SRK20ZM-S

  • Page 1 USER’S MANUAL AIR-CONDITIONER ENGLISH MANUEL DE L’UTILISATEUR FRANÇAIS CLIMATISEUR ANWENDERHANDBUCH DEUTSCH KLIMAGERA ¨ T ISTRUZIONI PER L’USO ITALIANO CONDIZIONATORE D’ARIA SRK20ZM-S SRK25ZM-S MANUAL DEL PROPIETARIO ESPAN ˜ OL SRK35ZM-S SRK50ZM-S ACONDICIONADOR DE AIRE GEBRUIKERSHANDLEIDING NEDERLANDS AIRCONDITIONING MANUAL DO UTILIZADOR PORTUGUÊS APARELHO DE AR CONDICIONADO ΟΔΗΓΙΕΣ...
  • Page 2 Air Conditioner Model name: Conformity model list [Indoor Unit] [Outdoor Unit] Category Model Category Model SRK Series SRK20ZM-S SRC Series SRC20ZM-S SRK25ZM-S SRC25ZM-S SRK35ZM-S SRC35ZM-S SRK50ZM-S SRC50ZM-S referred to in this declaration conforms with the following directives. Relevant EC Directives :...
  • Page 3: Table Of Contents

    Thank you for purchasing a MITSUBISHI HEAVY INDUSTRIES, LTD. Air-Conditioner. To get the best long-lasting performance, please read and follow this User’s Manual carefully before using your air-conditioner. After reading, please store the Manual in a safe place and refer to it for operational questions or in the event of any irregularities. This air-conditioner is intended for domestic use.
  • Page 4: Safety Precautions

    Safety precautions • Before starting to use the system, please read these “Safety precautions” carefully to ensure proper operation of the system. • When you have read this instruction manual, please keep it without missing. If someone else takes over as operator, make certain that the manual is also passed on to the new operator.
  • Page 5 ❚ Safety precautions CAUTION • Do not wash the air-conditioner with water. • Do not touch the aluminum fins on the air heat exchanger. This could cause an electric shock. • The system should only be used for its original It may result in injury.
  • Page 6: Name Of Each Part And Its Function

    Name of each part and its function INDOOR UNIT Air Inlet panel Draws the indoor air. Page 24 Air filter Removes dust or dirt from the inlet air. Page 24 Air-cleaning filter Page 25 Room temperature sensor Heat exchanger Air outlet Air blows out of here.
  • Page 7 Name of each part and its function Unit display section Remote control signal receiver Unit ON/OFF button This button can be used for turning on/off the unit when remote control is not available. Page 6 RUN (HOT KEEP) light (green) 3D AUTO light (green) •...
  • Page 8: Remote Control Handling

    Remote control handling Replacing the batteries The following cases signify exhausted batteries. Replace old batteries with new ones. • Receiving beep is not emitted when a signal is transmitted. • Display fades away. NOTE Pull out the cover and take •...
  • Page 9: Installing Two Air Conditioners In The Same Room

    Installing two air conditioners in the same room ■ When two air conditioners are installed in the same room, use this setting when the two air conditioners are not operated with one remote control. Set the remote control and indoor unit. Setting the remote control Setting an indoor unit Pull out the cover and take out batter-...
  • Page 10: Operation And Display Section For Remote Control

    Operation and display section for remote control Operation section Transmission section OPERATION MODE select button ON/OFF (luminous) button Press to start operation, press again to Each time the button is pressed, the stop. mode changes. Page 9,11 TEMPERATURE button FAN SPEED button This button sets the room temperature.
  • Page 11: Current Time Setting

    Current time setting ■ When inserting the batteries, the current time is automatically set to time setting mode. Mon and 13:00 are displayed as the current time. Set a correct day of the week and a time. Example: Set to Sat 10:30. Press the TIME SET UP switch.
  • Page 12: Temperature Adjustment During Auto

    Temperature adjustment during AUTO ■ Air temperature adjustment is possible even during automatic operation. There are 6 levels of adjustment possible with the button or button.During automatic operation, 24°C is preset both for heating and cooling. When a change in temperature is required. Press the“...
  • Page 13: Cool/Heat/Dry/Fan Mode Operation

    COOL/HEAT/DRY/FAN mode operation Point the remote control toward the air-conditioner, and Press the MODE select button. Set to a required mode. (Cool), (Heat), (Dry), (Fan) Press the ON/OFF button. Press the TEMP button. Press button for the preferred temperature. Recommendation Press the FAN SPEED button Airflow direction adjustment procedure.
  • Page 14: Airflow Direction Adjustment

    Airflow direction adjustment Adjusting airflow direction ■ Up/down direction can be adjusted with the AIRFLOW U/D (UP/DOWN) button on the remote control. Every time you press this button the mode changes as follows: Change on AIRFLOW (UP/DOWN) mode. (Flap stopped) (Swing) ■...
  • Page 15: Sleep Timer Operation

    SLEEP TIMER operation ■ The unit stops automatically after the set time lapses. The set temperature is automatically adjusted according to the elapsed time in order to avoid too much cooling or heating. Page 15 Press the SLEEP button. ■ If it is pressed while the unit is off SLEEP TIMER operation starts with the previous operation settings, and the air conditioning is turned off after the set time elapses.
  • Page 16: On-Timer Operation

    ON-TIMER operation ■ Operation starts 5 to 60 minutes before the set time so that the room temperature reaches the optimum temperature at the set time. Page 15 ON-TIMER operation can be set regardless of whether the air-conditioner is running or not. Example: In the case the preferred room temperature is required at 8:00.
  • Page 17: On-Timer + Off-Timer Operation

    ON-TIMER + OFF-TIMER operation ■ The timer operations of the combination of ON and OFF-TIMER. Example: When it is prefered to stop at 22:30, and then start operation at 8:00, near the set temperature. ■ OFF-TIMER operation setting Set by the procedures on page 13. Set to ■...
  • Page 18: Weekly Timer Operation

    WEEKLY TIMER operation ■ Up to 4 programs with timer operation (ON-TIMER / OFF-TIMER) are available for each day of the week. Max 28 programs per week are available. Once this has been set, the timer operation will be repeated at the same programs every week unless the WEEKLY TIMER is canceled.
  • Page 19 Setting mode <Individual setting> Set after setting the current day of the week and the time. Press the PROGRAM button. and current day of the week blink. Press the “ or (TIMER)” button. Select a day of the week to be reserved. Every time the button is pressed, the display is switched in the order of:...
  • Page 20 Press the “ or (TIMER)” button. Set a time. Every time the button is pressed, the display is switched in the order of: 0:00 0:10 0:20 1:00 1:10 (Units of ten minutes) Every time the button is pressed, the display is switched in the order of: 0:00 23:50 23:40...
  • Page 21 How to cancel the setting <Individual setting> Press the PROGRAM button. and current day of the week blink. Press the “ or (TIMER)” button. Select a day of the week to be cancelled. Press the SET button. The day of the week is determined and the program number blinks. Press the “...
  • Page 22: High Power/Economy Operation

    HIGH POWER/ECONOMY operation If the air-conditioner is not operating, point the remote control toward the air conditioner, and Press the ON/OFF button. Press the HI/ECO button. • When the operating mode is AUTO, COOL or HEAT Every time the HI/ECO button is pressed, the display is switched in the order of: No display (HIGH POWER)
  • Page 23: Night Setback Operation

    NIGHT SETBACK operation ■ During the cold season, the room temperature can be maintained at a comfortable level during the absence, at night, and while the room is unattended. The air conditioner maintains the constant temperature at about 10°C. Press the NIGHT SETBACK button. Every time the NIGHT SETBACK button is pressed, the display is switched in the order of: No display...
  • Page 24: Self Clean Operation

    SELF CLEAN operation ■ CLEAN operation should be run after AUTO, COOL and DRY operation to remove the moisture from inside the indoor unit and control the growth of mold and bacteria. In order to active CLEAN operation, press the CLEAN switch with the tip of a ballpoint pen.
  • Page 25: Installation Location Setting

    Installation location setting ■ Take the air conditioning unit’s location into account and adjust the left/right airflow range to maximize air-conditioning. If the air conditioning unit is running, press the ON/ OFF button to stop. The installation location setting cannot be made while the unit is running. Press the AIR FLOW U/D (UP/DOWN) button and the AIRFLOW L/R (LEFT/RIGHT) button together for 5 seconds or more.
  • Page 26: Maintenance

    Maintenance Before maintenance During the operational season Cleaning the air filter Standard interval is once Turn off the power supply. every two week • Pull up the air inlet panel forward. Remove the air filter • Lightly hold the knobs both sides and lift a little to remove the panel forward.
  • Page 27: Installing, Inspecting, And Replacing The Air-Cleaning Filter

    Cooling/heating is affected by an air filter clogged up with dust etc., and the operation noise becomes louder. It NOTE may also use extra electricity. Please clean the air filter at appropriate intervals. At the end of the season At the beginning of the season Perform the fan operation for 2 to 3 hours.
  • Page 28: Proper Installation

    Proper installation Suitable installation position • Do not put any obstruction in front of the indoor unit, preventing proper ventilation and functioning. • Do not install the unit in any of the following places: • Where there is a danger of leaking flammable gases. •...
  • Page 29: Notice

    Notice Restart is blocked for 3 minutes after you have stopped the op- The unit does not restart immediately after you have eration to protect the unit. stopped it. (RUN light is on) Please wait for three minutes. operating? The three-minute protection timer in the microcomputer auto- matically starts it up again.
  • Page 30: Contact Your Dealer

    Contact your dealer ■ Turn off the power switch immediately and inform your dealer in any of the following situations: The fuse or switch blows continu- The cable becomes extremely hot. ously. The covering of the cable is cracked. CAUTION Fuse often blows.

This manual is also suitable for:

Srk35zm-sSrk50zm-sSrk25zm-s

Table of Contents