Name
Parameter
Automatic restart after
162
instantaneous power failure
selection
Stall prevention operation level
165
for restart
Output current detection signal
166
retention time
Output current detection
167
operation selection
168
Parameter for manufacturer setting. Do not set.
169
170
Watt-hour meter clear
171
Operation hour meter clear
178
STF terminal function selection
STR terminal function
179
selection
180
RL terminal function selection
181
RM terminal function selection
182
RH terminal function selection
RUN terminal function
190
selection
Setting
Initial
Parameter
Range
Value
0, 1, 10, 11
1
0 to 200%
150%
0 to 10s,
0.1s
9999
0, 1
0
0, 10, 9999
9999
0, 9999
9999
0 to 5, 7, 8,
10, 12, 14,
16, 18, 24,
60
25, 37, 60,
62, 65 to 67,
9999
0 to 5, 7, 8,
10, 12, 14,
16, 18, 24,
61
25, 37, 61,
62, 65 to 67,
9999
0 to 5, 7, 8,
0
10, 12, 14,
16, 18, 24,
1
25, 37, 62,
65 to 67,
2
9999
0, 1, 3, 4, 7,
8, 11 to 16,
25, 26, 46,
47, 64, 70,
90, 91, 93,
95, 96, 98,
99, 100, 101,
103, 104,
107, 108, 111
0
to 116, 125,
126, 146,
147, 164,
170, 190,
191, 193,
195, 196,
198, 199,
9999
PARAMETER LIST
Name
A,B,C terminal function
192
selection
232
Multi-speed setting (speed 8)
233
Multi-speed setting (speed 9)
234
Multi-speed setting (speed 10)
235
Multi-speed setting (speed 11)
236
Multi-speed setting (speed 12)
237
Multi-speed setting (speed 13)
238
Multi-speed setting (speed 14)
239
Multi-speed setting (speed 15)
240
Soft-PWM operation selection 0, 1
Analog input display unit
241
switchover
244
Cooling fan operation selection 0, 1
245
Rated slip
Slip compensation time
246
constant
Constant-power range slip
247
compensation selection
Earth (ground) fault detection
249
at start
250
Stop selection
Output phase loss protection
251
selection
255
Life alarm status display
Inrush current limit circuit life
256
display
Control circuit capacitor life
257
display
Main circuit capacitor life
258
display
Main circuit capacitor life
259
measuring
Setting
Initial
Range
Value
0, 1, 3, 4, 7,
8, 11 to 16,
25, 26, 46,
47, 64, 70,
90, 91, 95,
96, 98, 99,
100, 101,
103, 104,
99
107, 108, 111
to 116, 125,
126, 146,
147, 164,
170, 190,
191, 195,
196, 198,
199, 9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
1
0, 1
0
1
0 to 50%,
9999
9999
0.01 to 10s
0.5s
0, 9999
9999
0, 1
1
0 to 100s,
1000 to
9999
1100s, 8888,
9999
0, 1
1
(0 to 15)
0
(0 to 100%)
100%
(0 to 100%)
100%
(0 to 100%)
100%
0, 1 (2, 3, 8,
0
9)
15