R-410a ductless split system floor console and heat pump

Advertisement

R -
Floor Console and Heat Pump
NOTE: Read the entire instruction manual before starting the installation.
Please read this Owner's Information Manual carefully before installing and using this appliance
and keep this manual for future reference.
For your convenience, please record the model and serial numbers of your new equipment in the
spaces provided. This information, along with the installation data and dealer contact information
will be helpful should your system require maintenance or service.
UNIT INFORMATION
Model #
Serial #
INSTALLATION INFORMATION
Date Installed
OWNERS MANUAL
-
- 410A Ductless Split System
MODELS: DLFBF - Indoor
SIZES: 09K, 12K, 18K
NOTE TO EQUIPMENT OWNER:
Specifications are subject to change without notice.

TABLE OF CONTENTS

SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
MODEL NUMBER REFERENCE . . . . . . . . . . . . ............. . . . . 3
PART NAMES AND THEIR FUNCTIONS . . . . . . . . . . . . . . . .. 4
OPERATING GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ................ .15
INSTALLATIONOF INDOORUNIT . . . . . . . . . . . . . . . . . . . . .17
ROUTINE CHECK AFTER INSTALLATION . . . . . . . . . . . . ..25
VOLUME OF REFRIGERANT . . . . . . . . . . . . . . . . . . . . . . . . . . 26
DEALERSHIP CONTACT INFORMATION
Company Name:
Address:
Phone Number:
Technician Name:
. . . . . . . . . . . . . . . . . . . . 5
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
. . . . . . . . . . . . . . ....................... . . . . . . .16
421 02 9260 00
PAGE

Advertisement

Table of Contents
loading

Summary of Contents for International comfort products DLFBHF09K1A

  • Page 1: Table Of Contents

    OWNERS MANUAL - 410A Ductless Split System Floor Console and Heat Pump MODELS: DLFBF - Indoor SIZES: 09K, 12K, 18K NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS ......2 MODEL NUMBER REFERENCE .
  • Page 2: Safety Considerations

    SAFETY CONSIDERATIONS CAUTION Installing, starting up, and servicing air- -conditioning equipment can be hazardous due to system pressures, electrical components, EQUIPMENT DAMAGE HAZARD and equipment location (roofs, elevated structures, etc.). Failure to follow this caution may result in equipment Only trained, qualified installers and service mechanics should damage or improper operation.
  • Page 3: Model Number Reference

    Positions 1 to 3 - Equipment type DLF = Indoor unit; DLC = Outdoor unit Model Numbers System Tons Unit Btuh Volt-Ph@60Hz Indoor Model Number 0.75 9000 208/230-1 DLFBHF09K1A 1.00 12000 208/230-1 DLFBHF12K1A 1.50 18000 208/230-1 DLFBHF18K1A Specifications are subject to change without notice.
  • Page 4: Part Names And Their Functions

    Part names and their functions OPERATION INSTRUCTIONS INDOOR UNIT CAUTION Before opening the front panel, be sure to Air outlet selection switch stop the operation and turn the breaker OFF. Do not touch the metal parts on the inside This setting blows air from upper outlet only.
  • Page 5: How To Use The Remote Control To Operate The Unit

    How to use the remote control to operate the unit OPERATION INSTRUCTIONS Remote Controller Description ON/OFF Press it to start or stop operation. : Press it to decrease temperature setting. : Press it to increase temperature setting. MODE Press it to select operation mode (AUTO/COOL/DRY/FAN/HEAT).
  • Page 6: How To Use The Remote

    How to use the remote control to operate the unit OPERATION INSTRUCTIONS Remote Controller Description ON/OFF : Press this button to turn on the unit .Press this button again to turn off the unit. Press this button to decrease set temperature. Holding it down above 2 seconds rapidly decreases set temperature.
  • Page 7: How To Use The Remote

    How to use the remote control to operate the unit OPERATION INSTRUCTIONS ress this button to achieve the on and off of healthy and scavenging functions in operation status. Press this button for the first time to start scavenging function; LCD displays“...
  • Page 8: How To Use The Remote

    How to use the remote control to operate the unit OPERATION INSTRUCTIONS QUIET: Press this button, the Quiet status is under the Auto Quiet mode (display " " and "Auto" signal) and Quiet mode (display " " singal) and Quiet OFF (there is no signal of " "...
  • Page 9 How to use the remote control to operate the unit OPERATION INSTRUCTIONS Combination of "MODE " and "-" buttons : About switch between Fahrenheit and centigrade " " " - " At unit OFF, press MODE buttons simultaneously to switch between Combination of "...
  • Page 10: Maintenance

    Maintenance OPERATION INSTRUCTIONS Before inspection and maintenance of the unit. PLEASE set power switch to “OFF” to cut off the power supply. Units Indoor unit, Outdoor unit and Remote controller 1. Wipe them with dry soft cloth. Front panel Open the front panel. Slide the two stoppers on the left and right sides inward until they click.
  • Page 11 Maintenance PERAT N NSTRUCT NS Titanium Apatite Photocatalytic 4. Clean or replace each filter. Air-Purifying Filter See figure. Air filter 5. Set the air filter and Titanium Apatite Photocatalytic Air-Purifying Filter as they were and close the front panel. inside the indoor unit. 6.
  • Page 12 Maintenance OPERATION INSTRUCTIONS Check Check that the base, stand and other fittings of the outdoor unit are not decayed or corroded. Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit. If no drain water is seen, water may be leaking from the indoor unit. Stop operation and consult the service shop if this is the case.
  • Page 13: Operating Guide

    Operating guide OPERATION INSTRUCTIONS Working principle and special functions for cooling Principle: Air conditioner absorbs heat in the room and transmit to outdoor and discharged, so that indoor ambient temperature decreased, its cooling capacity will increase or decrease by outdoor ambient temperature. Anti-freezing function: If the unit is running in COOL mode and in low temperature, there will be frost formed on the heat exchanger, when indoor heat exchanger temperature decreased below 32℉(0℃) ,...
  • Page 14 Operating guide OPERATION INSTRUCTIONS 421 02 9260 00 Specifications are subject to change without notice.
  • Page 15: Precautions

    Precautions OPERATION INSTRUCTIONS Specifications are subject to change without notice. 421 02 9260 00...
  • Page 16: Checking Before Contact The Serviceman

    Checking before contact the service man OPERATION INSTRUCTIONS PROBLEM CAUSES 421 02 9260 00 Specifications are subject to change without notice.
  • Page 17: Installationof Indoorunit

    Installation of indoor unit INSTALLATION INSTRUCTIONS CAUTIONS FOR INSTALLATION WHERE SELECTION OF INSTALLATION LOCATION. AIR CONDITIONER TROUBLEIS LIABLE Such a place where cool air can be distributed throughout the room. TOOCCUR. Such a place where condensation water is easily Where there is too much of oil area. drained out.
  • Page 18: Refrigerant Piping

    Installation of indoor unit INSTALLATION INSTRUCTIONS Refrigerant piping 1)Drill a hole ( 2 1/6 in (55 mm) in diameter ) in the spot indicated by the symbol in the illustration as below . 2)The location of the hole is different depending on which side of the pipe is taken out . 3)For piping ,see Connecting the refrigerant pipe ,under Indoor Unit Installation(1).
  • Page 19: Drain Piping

    Installation of indoor unit INSTALLATION INSTRUCTIONS Boring a wall hole and installing wall embedded pipe For walls containing metal frame or metal board ,be sure to use a wall embedded Inside Outside pipe and wall cover in the feed-through hole to prevent water leakage. Wall embedded pipe (field supply) Be sure to caulk the gaps around the pipes with caulking material to prevent...
  • Page 20 Installation of indoor unit INSTALLATION INSTRUCTIONS Installing indoor unit 3 tabs 1.Preparation Casing Open the front panel, remove the 4 screws and dis- mount the front grille while pulling it forward. Front grille Follow the arrows to disengage the clasps on the front case to remove it.
  • Page 21 Installation of indoor unit INSTALLATION INSTRUCTIONS The mounting plate should be installed on a wall which can support the weight of the indoor unit. 1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the boring points on the wall.
  • Page 22 Installation of indoor unit INSTALLATION INSTRUCTIONS Connecting the refrigerant pipe 1)Use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and gas leaks. Open-end wrench (fixed) Coat here with refrigeration oil Flare nut Wrench Connection pipe Indoor unit tubing 2)Align the centres of both flares and tighten the flares and tighten the flare nuts 3 or 4 turns by hand.
  • Page 23 Installation of indoor unit INSTALLATION INSTRUCTIONS Checking for gas leakage 1)Check for leakage of gas after air purging 2)See the sections on air purges and gas leak checks in the installation manual for the outdoor unit. Check for leakage here Apply soapy water and ch- eck carefully for leaking gas.
  • Page 24 Installation of indoor unit INSTALLATION INSTRUCTIONS Live the sensor securing plate, remove the front metal plate cover, and connect the branch wiring to the terminal block. 1)Strip wire ends 2)Mach wire colours with terminal numbers on indoor and outdoor unit’s terminal blocks and firmly screw wires to the corresponding terminals.
  • Page 25: Routine Check After Installation

    Routine check after installation INSTALLATION INSTRUCTIONS Check after installation Items to be checked Possible malfunction Situation Has it been fixed firmly? The unit may drop,shake or emit noise. It may cause insufficient refrigerating capacity. Have you done the refrigerant leakage test? Is heat insulation sufficient? It may cause condensation and dripping.
  • Page 26: Configuration Of Connection Pipe And Additional Volume Of Refrigerant

    Configuration of connection pipe and additional volume of refrigerant INSTALLATION INSTRUCTIONS 1. Standard length of connection pipe 16.4 ft (5 m) 、24.6 ft (7.5 m) 、26.25 ft (8 m) 2. Min length of connection pipe For the unit with standard connection pipe of 16.4 ft (5 m), there is no limitation for the min length of connection pipe.
  • Page 27 Configuration of connection pipe and additional volume of refrigerant INSTALLATION INSTRUCTIONS Sheet 2. Additional refrigerant charging amount for R410A Diameter of connection pipe mm Indoor unit throttle Outdoor unit throttle Liquid pipe Gas pipe Cooling only, Cooling only Cooling and cooling and heating heating 3/8 in (9.5 mm) or...
  • Page 28 66129918094 Copyright 201 5 International Comfort Products Lewisburg, TN 37091 USA 421 02 9260 00 Specifications are subject to change without notice.

This manual is also suitable for:

Dlfbhf18k1aDlfbhf12k1a

Table of Contents