Install Outdoor Unit - GE AIR 116 IN Service Manual & Installation Manual

Split system air conditioner
Table of Contents

Advertisement

Install Outdoor Unit

11.3
1 Install connecting pipe
The flare end of the connecting pipe coincides with the flare end connector of the corresponding valve
Tighten nuts on connecting pipe forcibly then tighten it by spanner (as shown in Fig.11.7)
Note: Too great of torque would damage nuts.
Refer the following list
for tightening torque
Connect pipe nut
2 Distribution line connection
Disassemble the right side board of the outdoor unit, drill
hole for connection of the outdoor unit and sheath with
line passing rubber ring;
Disassemble line clamp, connect the power lines to the
terminal board and fix them as shown in Fig.11-9. Take
off the clamp, connect and fix the power connect lines to
the wiring terminal board (as shown in Fig.11.8);
With line clamp, fix the power lines and signal control
line. Connect the corresponding connectors properly
Ensure that wire has been fixed firmly
Install Front side plate
Remark
W r o n g w i r i n g c o n n e c t i o n w i l l c a u s e f a i l u r e o f s o m e e l e c t r i c
components
The lead between the connecting and the fixed should be a little
freedom when fixing it with wire clamp.
Torque Spanner
Joint
Fig.11-7
Front side plate
Hex nut diameter
Diameter 6
Diameter 9.5
Diameter 12
Diameter 16
Spanner
Control Cord
(Fig.11-8)
33
Tighten torque(N-M)
15-20
31-35
50-55
60-65
Earthing Copper wire
Orange
Blue
Black
B r o w n
L i n e
Clamp
Power Cable
Rear side Plate
Line Passing hole for outdoor unit
Interconnection Cable
Yellow-Green
Purpl e