Installing the outdoor unit

Choose installation location
1. Select a location where noise and outflow
air will not inconvenience neighbors.
2. Select a location with sufficient ventilation.
3. The inlet and outlet should never be
blocked or covered.
4. The location should be able to withstand
the full weight and vibration of the unit.
5. Avoid installation in any area where a
danger of flammable gas or of corrosive
gas leaks exists.
6. Ensure that the installation location
conforms to the requirements of the
installation dimension diagram.

Install the connection pipe

1. Align the center of the piping flare with
the relevant valve.
2. Fasten the nut to the flare by hand and
then tighten the nut with torque wrench
to specifications listed in table below.
Refer to Fig. 3.
3. Cover piping joints with pipe cover.
4. Insulate piping with thermal insulation
hose provided with the unit.
Note: excessive tightening torque will
damage the flare surface. Use table 4 to
identify the appropriate torque.
Fig. 3
Indoor unit piping
Spanner
Page 25
Taper nut
Piping
Torque
wrench
Table 4
Pipe diameter
(mm)
6,35
9,52
12,7
15,8

Electrical wiring connection

Refer to table 1, table 2 and table 3 to
identify the required electrical wiring for
your air-conditioner.
1. Remove the wiring cover.
2. Remove wire clamp(s).
3. Connect the wires to the terminal block
strictly based on the correspondence
between the wire colors and the terminal
block codes provided in table 2. Clamp
the connected cord onto the chassis.
4. Make sure each wire is connected to the
right terminal pin of the outdoor terminal
block and corresponds to the right
terminal pin of the indoor unit.
5. Make sure that the wiring has been
connected firmly.
6. Re-assemble cover.
NOTE:
• Wrong wire connections will cause
electrical malfunction.
• Do not pull down the connecting cable
when fixing it with the wire clamp.
• Make sure the wires are securely
connected to the terminal block and the
connecting cable is firmly held by the
wire clamp.
Torque
(Nm)
15-20
31-35
50-55
60-65
25