Operation procedures/pictures
8.1.7
Disassemble the motor
Loose the screw fixing the motor clamp plate
with a screw driver and remove the motor
clamp plate. Screw off 1 M4 fastening screw
at the axle sleeve and remove the motor.
As shown in Fig.8-10
8.1.8
Disassemble Cross Flow Fan
The cross flow fan can be removed after re-
moving the bearing rubber gasket from the
left.
As shown in Fig.8-11
Motor clamp plate
Motor
Fastening Screw
Screw
Cross flow fan
Bearing rubber
19
Fig.8-10
Fig.8-11