GPS Grandmaster Clock

2.10 TTL Electrical Outputs

RT430 has 4 electrical output, 2 screw connector, and 2 BNC connector. One output of each connector type
is insulated, as
Figure 14
See
Chapter 1
for more description of signal levels and maximum charge.
The type of signal at each output can be configured through a Web Interface to generate IRIG-B004, DCF77,
1PPS, 1PPM, 100PPS, or any custom-defined low frequency, from 1 pulse-every-two-seconds to 1 pulse-
per-day. It is also possible to configure the outputs to generate daily set-time pulses. The polarity of the
signal can also be configured. For details on the configuration of TTL-Level electrical outputs, refert to
Chapter
4.

2.11 Open-collector electrical outputs

RT430 has 2 open-collector electrical outputs, shown in
See
Chapter 1
for description of signal levels and maximum charge.
The type of signal at each output can be configured through a Web Interface to generate IRIG-B004, DCF77,
1PPS, 1PPM, 100PPS, or any custom-defined low frequency, from 1 pulse-every-two-seconds to 1 pulse-
per-day. It is also possible to configure the outputs to generate daily set-time pulses. The polarity of the
signal can also be configured. For details on the configuration of open-collector electrical outputs, see
Chapter 4
36
shows.
Figure 14: TTL level electrical outputs
Figure 15: Open collector electrical outputs
Figure 15
.
RT430-TM-EN-5