Product Specifications
Power consumption
AC input voltage and frequency
DC power rating
Power connector
Table 10: Environmental Specifications
Description
Operational temperature
Nonoperational temperature
Non-operational temperature
(Transportation or Storage, or
both)
Operational humidity
Cisco ASR 901S Series Aggregation Services Router Hardware Installation Guide
84
• DC-input power and power dissipation:
◦ 40 W for all DC models
• AC-input power and power dissipation:
◦ 40 W without PoE+
◦ 70 W with 1 PoE+ (1-sec backup)
◦ 100 W with 2 PoE+ ports (1-sec backup on 1 PoE+ port only)
100-240 Vac, 50-60 Hz
• DC-input voltage rating: 24 VDC, -48 VDC, -60 VDC
• DC-input current rating: 2.5 A maximum
• DC power connector with four-pin connector with 1 m cable (part
number: 72-5561-01)
• DC power connector with four-pin connector with 10 m cable (part
number: 72-5568-01)
• AC connector
Specifications
-40 to 149°F (-40 to 65°C); optics used may limit the temperature range
-40 to 114.8°F (-40 to 46°C) plus solar radiation (GR-3108 Issue 2,
Class 4)
-40 to 158°F (-40 to 70°C)
-40 to 113°F (-40 to +45°C) with solar loading
-40°F (-40°C) for 72 hrs
158°F (70°C) for 72 hrs
Section 4.1.1.1 of GR-63 or Section 9.1 of ATIS-0600010.2007
104°F (40°C) and 95% RH for 96 hrs
Section 4.1.1.3 of GR-63 or Section 9.3 of ATIS-0600010.2007
<5% to 100%, RH condensing (GR-3108, Issue 2, Class 4)
Specifications and Part Numbers