Gemini Software Operation
Example screenshot of sonar imagery with a 25% compression level.
Acquisition Speed
Acquisition speed is another mechanism available for reducing the sonar data rate and
required bandwidth. When the Half
background) the software will reduce the sonar image acquisition speed to approximately
half the maximum rate.
Serial Inputs
Data from external serial sensors can input to the software via a Gemini Hub or the computer
COM Ports. These options can be enabled/disabled using the provided drop-down menus.
See Section 5.3, "Serial Data Input" for a detailed description of the related settings and
options.
Reset to Defaults
The Reset to Defaults button, when pressed, returns the software settings to their default
values.
Document: 0685-SOM-00001, Issue: 11
Note
Compression is applied before the software receives the sonar data and
therefore compression cannot be applied to data that has already been recorded.
Conversely, recorded data that has been compressed cannot be uncompressed.
Note
Reducing the acquisition speed can also be useful if acoustic multipath is causing
false moving/transient targets to be observed in the sonar image.